Pin
Signal
5
Start print
6
End print
7
Reprint
8
Reserved
PX940 Applicator Interface Installation Instructions
Type
Description
Pulse mode - prints one and only one label
Input
whenever this pin is pulled to ground. Signal
must be de-asserted and re-asserted to print
another label.
• Printing starts on HIGH to LOW transition if
format is ready.
• De-assert this signal to HIGH to inhibit
printing.
Level mode - prints labels continuously
when this pin is pulled to ground. Printing is
disabled when signal is de-asserted. If a label
is printing when de-asserted, printing stops
after that label is complete.
• Assert LOW to start printing if format is
ready.
• De-asserted HIGH when current label
has finished printing. Remains
de-asserted while waiting for next label
to be ready to print.
Output
Drives an applicator or other external device
requiring synchronization with the print
cycle. Choose between four types of output
signals:
• Type 1 (Default): Asserted LOW for 20ms
when label has finished printing and
positioned. Not asserted during continuous
printing.
• Type 2: Asserted HIGH for 20ms when label
has finished printing and positioned. Not
asserted during continuous printing.
• Type 3: Asserted LOW only when media is
moving, otherwise de-asserted HIGH.
• Type 4: Asserted HIGH only when media is
moving, otherwise de-asserted LOW.
Input
Enables Reprint mode via software. When
this mode in enabled, assert LOW to reprint
last label. This input is ignored when Reprint
mode is disabled.