CHECKING THE OPERATION OF THE PROTECTION CIRCUIT
When the output ·circuit is repaired by replacing the
power transistors, etc., perform an operation check on
the ASO (Area of Safe Operation) detection circuit and
the speaker protection circuit.
1. Operation check of the ASO detection circuit
for the output transistors
Connect the audio oscillator to the TUNER IN ter-
minals with the speaker terminals unloaded (speaker:
disconnect). Set the frequency of the audio oscillator
at 1 kHz and adjust the level of the input signal so
that the voltage at the speaker terminals is approx. 5
V rms.
Under these conditions, short-circuit the speaker ter-
minals of the channel to which the input signal is ap-
plied using a lead wire, etc. If this sl:lort-circuit makes
the ASO detection circuit operate, no output appears
at the speaker terminals even if the lead wire used for
short-circuiting is removed.
Next, turn off the power switch and, after approx. 10
sec., turn the power switch on again. When output
comes out of the speaker terminals, this indicates
that the ASO detection circuit is operating normally.
2.
Operation check of the speaker protection cir-
cuit
Make sure that the relay operates (a click sound is
heard) approx. 6-10 seconds after the power switch
is turned on with the speaker terminals unloaded
(speaker: disconnect).
Next, when a resistor with a resistance of approx-
imately 10 k ohms and two 1.5 V dry batteries are
connected in series across pins 4 and 2 of main
power printed wiring board IC901, the relay turns off
within 1 sec. When the dry batteries are taken away,
the relay operates again. Next, change the polarities
of the dry batteries and carry out the abovemention-
ed operation to check the operation of the relay.
If the relay is energized with this operation, it means
that the speaker protection circuits are functioning
normally.
When conducting this operational check, take care
not to create shortcircuits with parts close at hand.
3.
Operation check of temperature-detection cir-
cuit
Leave the speakers disconnected without a load, set
the power switch to ON and check that a clicking
sound is heard by the relay being energized after a
period of 6 to 10 seconds.
Next, warm up the SR901 body using a soldering iron
or a hair dryer. Once the temperature of the body
reaches about 100°C, the protection circuit is ac-
tivated and the relay is turned OFF. Even if the body
is no longer warmed up, the relay is not reset. Next,
set the power switch to OFF and after allowing the
body to cool down sufficiently, switch ON the power
again. If the relay is energized, it means that the
temperature-detection protection circuit is operating
normally.
CAUTION
Before warming up the body, detach the clamp and
distance the SR901 from the radiation fin. When a
soldering iron of the 30 watts class is used and the body
is warmed up too much, the devices themselves may be
damaged. Take care not to apply heat for a long period
of time.
Method of checking the POWER MOS FET---...
Remove the FET.
In the case of an N channel FET, it is normal: When
touching the black test probe of the tester (ohm
range X100) to the drain of the FET, and the red test
probe to the source, after applying the black test pro-
be to the gate and the red test probe to the source at
the same time, a current flows. And next, when
brushing both the gate and source simultaneously
with your hand, the current stops.
In the case of a P channel, the red and black test pro-
bes of the tester are applied in reverse.
Audio oscillator
Frequenzgenerator
Oscillateur ci'onde
sonore
-12-
AC voltmeter
Wechselstrom
Voltmeter
Voltmetre a
Courant alternatif
SR901
Oscilloscope
Oszillograph
Oscilloscope
Fig. 1
Abb. 7
Fig.
8
Abb.
8
Fig. 9
Abb. 9
• Phenomena and remedy when the protection circuit operates
Type of protection circuit
Phenomenon when the protection
Cause
Remedy
circuit operates
1
Muting circuit
No sound comes out about 6-10
Normal
sec. after the power switch is
turned ON.
2
Protection circuit of the
1.
No sound comes out.
Short circuit of speaker
Turn off the power switch, check
POWER MOS FET (ASO
2. When the power switch is
output terminal.
whether the speaker terminal is short
protection circuit)
turned ON, the relay becomes
circuited or not, and turn ON again.
ON, then OFF when the signal
is applied.
3
Speaker protection circuit
1.
No sound comes out.
Power amplifier faulty,
1.
Repair faulty parts in power
(DC voltage detec-
2. Neutral point voltage is more
etc.
amplifier.
.tion/protection circuit)
than ±2 V.
3.
After the power switch is
turned ON, relay doesn't turn
ON.
4
Temperature-detection pro-
1 .
Sound suddenly stops when
1.
Poor heat
1.
Improve heat dissipating effect.
tection circuit
used for a long time.
dissipating effect.
2. Use speakers with an impedance
2. Speaker impedance
of not less than 6 ohms or avoid
is too low.
use at sound volume levels.
KONTROllE DER FUNKTION DER SCHUTZSCHAl TUNG
Falls die Ausgangsschaltung repariert wurde, indem
z.b. die Leistungstransistoren usw. erneuert wurden,
dann mur5 die ASO-Schutzschaltung (ASO
=
Area of
Safe Operation) und die Lautsprecher-Schutzschaltung
kontroliert werden.
1.
Funktionsprufung der ASO-Schaltung fur die
leistu n gstra nsisto ren
Den
Frequenzoszillator
an
die
TUNER
IN
anschlier5en, wobei die Lautsprecherklemmen keine
Last
aufweisen
durfen
(Lautsprecher
nicht
angeschlossenl.
Die
Frequenz
des
Frequen-
zoszillators auf 1 kHz einstellen und den Pegel des
Eingangssignales so abgleichen, dar5 die Spannung
an den Lautsprecherklemmen etwa 5 V (Mittelwert,
bewertet) betragt. In diesem Zustand sind die Laut-
sprecherklemmen kurzzuschlier5en, und zwar die
Klemmen
jenes
Kanals,
an
welchen
das
Eingangssignal angelegt wurde. Falls dieser Kurz-
schlur5
zu
einem
Ansprechen
der
ASO-
Schutzschaltung
fUhrt,
dann
erscheint
kein
Ausgangssignal an den Lautsprecherklemmen, auch
nicht wenn den zum Kurzschlier5en der Klemmen
verwendete Draht entfernt wird.
Danach den Netzschalter abschalten und nach etwa
10 Sekunden wieder einschalten. Wenn nun ein
Ausgangssignal
an
den
Lautsprecherklemmen
festgestellt wird bedeutet dies, dar5 die ASO-
Schutzschaltung richtig arbeitet.
2.
Funktionsprufung
der
lautsprecher-
Schutzschaltung
Darauf achten, dar5 etwa 6-10 Sekunden nach dem
Einschalten des Netzschalters ein Schaltgerausch
des Relais vernommen werden kann, wenn keine
Last
an
den
Lautsprecherklemmen
anliegt
( Lautsprecher nicht angeschlossen).
Wenn ein Widerstand mit einem Widerstand von ea.
10 kOhm und zwei 1,5 V Trockenbatterien in Serie
-13-
mit Stift 4 und Stift 2 von IC901 der gedruckten
Schaltung parallelgeschaltet werden, wonach das
Relais innerhalb einer Sekunde abschalten sollte.
Werden die Trockenbatterien wieder entfernt, dann
arbeitet das Relais wiederum. Anschlier5end die
Polaritat der Tockenbatterien umpolen und die obige
Prufung des Relais nochmals durchfUhren. Wenn
auch nun das Relais aktiviert wird, dann ist die
Lautsprecher-Schutzschaltung
in
Ordnung.
Bei
dieser PrOfung ist besonders darauf zu achten, dar5
keine
der
benachbarten
Teile
kurzgeschlossen
werden.
Wird das Relais dadurch erregt, bedeutet es, dar5 die
Schutzschaltkreise der Lautsprecher normal funk-
tionieren.
Wenn diese Funktionsprufung vorgenommen wird,
darauf
achten,
dar5
keine
Kurzschlusse
mit
naheliegenden Teilen entstehen.
3.
Funktionsprufung
des
Warmeentdeckungs-
Schaltkreises
Die Lautsprecher ohne Belastung getrennt lassen,
den Netzschalter einschalten und uberprufen, dar5
nach 6 bis 10 Sekunden durch Erregen des Relais ein
Knackgerausch gehart wird.
Danach den Karper des S R-901 mit einem Lotkolben
oder Haartrockner anwarmen. Wenn die Temperatur
des Korpers ea. 100°C erreicht, wird der Schutz-
schaltkreis aktiviert und das Relais ausgeschaltet.
Selbst wenn der Karper nicht weiter erwarmt wird,
erfolgt keine Ruckstellung des Relais. Als nachstes
den Netzschalter ausschalten, und nachdem sich der
Karper genugend abgekuhlt hat, das Gerat wieder
einschalten. Wird das Relais erregt, bedeutet es, daf?:.
der Warmeentdeckungs-Schutzschaltkreis
normal
funktioniert.