Siemens RUGGEDCOM RSG2100 Installation Manual page 54

Rugged ethernet switches
Hide thumbs Also See for RUGGEDCOM RSG2100:
Table of Contents

Advertisement

a
Siemens-specified severity levels
EMC Immunity Type Tests per IEEE 1613
Note
The RUGGEDCOM RSG2100 meets Class 2 requirements for an all-fiber configuration
and Class 1 requirements for copper ports. Class 1 allows for temporary communica-
tion loss, while Class 2 requires error-free and interrupted communications.
Radiated RFI
Fast Transient
Oscillatory
HV Impulse
RUGGEDCOM RSG2100
Installation Manual, 03/2020, C79000-G8976-1040-17
Test
IEC 60255-5
Dielectric Strength
HV Impulse
Description
ESD
Enclosure Contact
Enclosure Air
Enclosure Ports
Signal Ports
DC Power Ports
AC Power Ports
Earth Ground Ports
Signal Ports
DC Power Ports
AC Power Ports
Signal Ports
DC Power Ports
AC Power Ports
Dielectric
Signal Ports
Strength
DC Power Ports
AC Power Ports
6.2 EMC and Environmental Type Tests
Description
Signal Ports
DC Power Ports
AC Power Ports
Signal Ports
DC Power Ports
AC Power Ports
Test Levels
Severity Levels
60% for 0.1 s
100% for 0.05 s
2 kV (Fail-Safe
Relay Output)
2 kV
2 kV
5 kV (Fail-Safe
Relay Output)
5 kV
Test Levels
±2 kV
±4 kV
±8 kV
±4 kV
±8 kV
±15 kV
35 V/m
4 kV @ 2.5 kHz
4 kV
4 kV
4 kV
2.5 kV Common Mode @ 1 MHz
2.5 kV Common
1 kV differential mode @ 1 MHz
2.5 kV Common
1 kV differential mode @ 1 MHz
5 kV (Fail-Safe Relay Output)
5 kV
5 kV
2 kV
2 kV
2 kV
Certification
 
 
 
 
 
 
45

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Simatic netSimatic net ruggedcom rsg2100Rsg2100

Table of Contents