How To Connect Electrical Wires And Sensors; How To Connect Wiring To The Terminal - Panasonic PAW-VP1000LDHW Technical Manual

Air-to-water heat pump systems, domestic hot water system for r410a and r32 use
Hide thumbs Also See for PAW-VP1000LDHW:
Table of Contents

Advertisement

7.4

How to connect electrical wires and sensors

7.4.1 How to connect wiring to the terminal

Proceed as follows:
1. A screwdriver is inserted with a rocking motion to the stop.
2. The screwdriver is captivated, holding the CAGE CLAMP open, while the wire is
inserted.
3. The screwdriver is withdrawn and the wire is automatically dumped.
PAW-VP•LDHW - Technical Manual – 2019-11
Electrical Wiring
Strip 10 mm
Insulation tape Shield mesh
Shield mesh
7
95