Download Print this page

Sealey LP14.V2 Manual page 3

15,354btu/hr space warmer propane heater with stand

Advertisement

7.3.
MAINTENANCE
7.3.1.
Any repairs must be performed by specialised personnel and using original replacement parts.
7.3.2.
To ensure proper operation of the burner, we recommend annual maintenance, performed at an authorised service centre.
DO NOT make any modifications to the heater, it is dangerous!
8
NOTE: Spiders or small insects could take up residence inside the burner or nozzle altering the
flow of gas and combustion. Inspect them frequently.
8. TROUBLESHOOTING
FAULT
Gas leak
Inefficient combustion across the ceramic
plaque
Burner flame extinguishes during operation
Heater will not light
ENVIRONMENT PROTECTION
Recycle unwanted materials instead of disposing of them as waste. All tools, accessories and packaging should be sorted, taken to
a recycling centre and disposed of in a manner which is compatible with the environment. When the product becomes completely
unserviceable and requires disposal, drain any fluids (if applicable) into approved containers and dispose of the product and fluids
according to local regulations.
Note: It is our policy to continually improve products and as such we reserve the right to alter data, specifications and component parts without prior
notice.
Important: No Liability is accepted for incorrect use of this product.
Warranty: Guarantee is 12 months from purchase date, proof of which is required for any claim.
Sealey Group, Kempson Way, Suffolk Business Park, Bury St Edmunds, Suffolk. IP32 7AR
01284 757500
© Jack Sealey Limited
POSSIBLE CAUSE
Regulator and hose connection.
Valve and hose connection.
Split or perished hose
POL nut connection
Missing piece of ceramic fire clay
Gas jet holes blocked
Low gas or empty bottle.
Thermal element not hot enough
The wind has extinguished the flame
Thermal element faulty
Faulty manual valve
Gas cylinder valve is closed
Volume control not opened fully when
attempting ignition.
Insects inside the burner
01284 703534
sales@sealey.co.uk
Original Language Version
REMEDY
Brush a solution of washing up liquid and
water on to all connections and look for
active bubbles. Tighten clips or replace hose
Check POL nut fitting is tight (ACW)
Replace plaque or repair with PYRUMA (fire
cement) and leave to set for approximately
48 hours.
Clear blockages
Change the gas bottle
Go through the start up procedure again.
Allow to cool before restarting. Move
appliance away from draughts
Replace the thermocouple. Contact your
Sealey stockist
Replace the valve. Contact your Sealey
stockist
Turn on the gas cylinder control, check for
leaks.
Read instructions 6.2. ignition process.
Clear blockages
www.sealey.co.uk
LP14.V2 Issue: 6 (ERP) - 31/07/19

Advertisement

loading

This manual is also suitable for:

Space warmer lp14.v2