TP48200A-HX09A2 & TBC300A-TCA2
Installation Guide
Cover the cable outside the cabinet with a corrugated pipe.
7.1 (Optional) Installing Dry Contact Signal Cables
Procedure
Step 1 Press the contact plate using a flat-head screwdriver to flip the metal spring inside each dry
contact.
Step 2 Connect the signal cables to the corresponding dry contacts.
Step 3 Put away the flat-head screwdriver and check that the signal cables are securely connected.
Figure 7-1 Installing a dry contact signal cable
(1) Contact plate
----End
Issue 01 (2013-10-25)
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
7
Installing Cables
(2) Dry contact port
7 Installing Cables
57