Coil # 2
•
Wind coil #2 the same as coil #1, with the exceptions of:-
•
The original wire length is 45mm for coil #2.
•
With free end of the original wire, solder to the amplifier input on the PCB side of the Rx Module.
•
33 pF Capacitor is placed on left hand side of coil. [alongside of shield]; place capacitor in first, then coil,
then solder.
•
Place into coil position #2 of Rx module.
•
Solder original wire to RF amplifier input connection
tweezers to help you. [see solder points on page 28]
Coil # 3
•
Wind coil #3 the same as coil #1, with the exceptions of:-
•
The original wire length is 50mm for coil #3.
•
With free end of the original wire, solder to the amplifier output on the PCB side of the Rx Module.
•
Push one end of the bent 0.8mm wire through a right hand hole of the square end of the coil former [for
earth connection]
•
33 pF Capacitor is placed on right hand side of coil. [alongside of shield]
•
Place into coil position #3 of Rx module.
•
Solder original wire to RF amplifier output connection on rear PCB side of Rx Module. Use a pair of
tweezers to help you. [see solder points on page 28]
Philips FM92E Conversion to 6 Meters:
on
rear PCB side of Rx Module. Use a pair of
Version 3.9
Page 44