Icemaker drain pump

Advertisement

STEP 6 Connect Water Supply
For connection in Front at Water Valve:
• Feed water supply tubing through one of the two
access holes in the rear cover.
• Slide the icemaker into its permanent location.
IMPORTANT: Check to be sure water and drain lines
do not kink or bind. This could interfere with
icemaker operation.
Water
Inlet
Water
Outlet
• Bend the tubing to meet the connection at the water
valve inlet at the front.
• Remove the water valve inlet cover and attach copper
tubing with a compression nut and sleeve.
• Check to be sure copper tubing does not touch the
side wall or other parts inside the cabinet.
• Turn on the water and check all connections for
leaks.
STEP 7 Finalize Installation
• Connect power.
• Push selector switch to ON.
• Wait for rinsing cycle, approximately 5 minutes, to be
sure the icemaker is operating properly.
Pub. No. 49-60155
For Water Connection at Rear:
Water
Line
Access
Holes
• For threaded connection, use ferrule and compres-
sion nut to secure the line as shown on page 1.
• For water tube exiting rear access cover, connect
water line using 1/4" union or coupling.
• Check to be sure copper tubing does not touch the
side wall or other parts inside the cabinet.
• Turn on the water and check all connections for
leaks.
SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE
From Drain Pump
Drain Hose
From Drain
Pump
Coupling
(Not Supplied)
Nut
(Supplied)
Ferrule
(Not Supplied)
Line to
Icemaker
Vent Hose
Water
Supply
Line
Nut
(Supplied)
DWG. NO. 197D4493P001