NOTICE
Damage due to use of incorrect coupling or cabinet bushings on DRIVE-CLiQ connections
Damage or malfunctions can occur on the devices or system if incorrect or unreleased
couplings or cabinet bushings on DRIVE-CLiQ connections are used.
• Only use the DRIVE-CLiQ couplings and DRIVE-CLiQ cabinet bushings described in
11.3

Information on electromagnetic compatibility (EMC)

11.3.1

General information

Requirements to implement EMC are listed in EN 61800-3 and in the "EMC installation
guideline" Configuration Manual (Article No. 6FC5297-0AD30-0.P.). Conformance with the
EMC Directive of the EC can be ensured by following the measures described in the "EMC
installation guideline" Configuration Manual.
When mounting components in cabinets, in order to fulfill the EMC Directive, the following
conditions must be additionally observed:
● Connected to TN or TT line supply systems with grounded neutral point
● SINAMICS line filter
● Observance of information about cable shielding and equipotential bonding
● Use of the recommended power and signal cables from Siemens.
● Only use cables from Siemens for the DRIVE-CLiQ connections (see Chapter DRIVE-
CLiQ signal cables (Page 377))
AC Drive
Manual, 06/2019, 6SL3097-5AL00-0BP1
Chapter Accessories (Page 349).
Cabinet design and EMC for components, Blocksize format
11.3 Information on electromagnetic compatibility (EMC)
367