A.2

RF180C

Area of application
The RF180C communications module is a module for connecting Siemens Ident devices to
PROFINET. The RF180C communications module can be connected both to SIMATIC S7
controllers as well as to any other controllers. Up to two readers can be operated on the
RF180C at the same time. The user can start a command on 2 readers simultaneously (FB
45 when operating on a SIMATIC S7).
Figure A-3
Hardware configuration
The RF180C is integrated into the hardware configuration by means of a GSDML file. The
RF180C can then be configured using HW Config of the SIMATIC manager or another
PROFINET tool. The GSDML file can be found on the "RFID Systems Software &
Documentation" DVD or on the Internet (see section "Service & Support (Page 121)").
● GSDML-V2.2-SIEMENS-RF180C-date in format "yyyymmdd.xml"
● The RF180C must have a valid IO device name. The default device name is RF180C
Parameter setting by means of GSDML file
The GSDML file contains four parameters relevant to RFID that must be set. They are set by
selecting the "Object properties" for slot 0 of the RF180C in HW Config.
FB 45 for MOBY U, MOBY D, RF200, RF300
Function Manual, 07/2012, J31069-D0166-U001-A4-7618
Configurator for RF180C
Brief description of the hardware
A.2 RF180C