Download Print this page

GE IP180 Series Installation Manual

Advertisement

Quick Links

GE
Lighting Solutions
GE LED Luminaire
(IP180 Series)
Features
• 0-10V & DALI control (optional)
• Long life (50,000 hour rated life)
• 5 year warranty
• Dry location rated
BEFORE YOU BEGIN
Read these instructions completely and carefully.
RISK OF ELECTRIC SHOCK
• Turn power off before inspection, installation or removal.
• Properly ground electrical enclosure.
RISK OF FIRE
• Follow all NEC and local codes.
• Use only UL approved wire for input/output connections.
Minimum size 18 AWG.
Save These Instructions
Use only in the manner intended by the manufacturer. If you have any questions, contact the manufacturer.
Tools and components required:
• #2 Phillips head screwdriver.
• UL Recognized conduit connections per NEC/CEC for nominal conduit trade sizes ½" or ¾".
• UL Recognized wire connectors.
Prepare Electrical Wiring
Electrical Requirements
• The LED driver must be supplied with 100-277 VAC, 50/60 Hz and connected to an individual properly
grounded branch circuit, protected by a 15 or 20 ampere circuit breaker. Use min. 75°C supply conductor.
Grounding Instructions
• The grounding and bonding of the overall system shall be done in accordance with National Electric Code
(NEC) Article 600 and local codes.
imagination at work
WARNING/AVERTISSEMENT
RISQUES DE DÉCHARGES ÉLECTRIQUES
• Coupez l'alimentation avant d''inspecter, installer ou déplacer le luminaire.
• Assurez-vous de correctement mettre à la terre le boîtier d'alimentation électrique.
RISQUES D'INCENDIE
• Respectez tous les codes NEC et codes locaux.
• N'utilisez que des fils approuvés par UL pour les entrées/sorties de
connexion. Taille minimum 18 AWG.
Installation Guide

Advertisement

loading

Summary of Contents for GE IP180 Series

  • Page 1 Installation Guide Lighting Solutions GE LED Luminaire (IP180 Series) Features • 0-10V & DALI control (optional) • Long life (50,000 hour rated life) • 5 year warranty • Dry location rated BEFORE YOU BEGIN Read these instructions completely and carefully.
  • Page 2 Unit Installation The luminaires come as a separate master luminaire and a satellite luminaire which must always be installed as a pair. When installing multiple pairs always ensure that adjacent luminaire are of alternating types. The master luminaire differs from the satellite luminaire in that it has an LED driver.
  • Page 3 Electrical Connections Remove knockout plate from luminaire by loosening the Carefully remove appropriate knockout for AC line input knockout screw and sliding the cover out of luminaire. wires (inner knockout for ½” conduit, outer knockout for ¾” conduit). Install listed electrical fittings in the knockout holes for wire protection and pass supply conduit through electrical fittings.
  • Page 4: Specifications

    GE Lighting Solutions, LLC is a subsidiary of the General Electric Company. The GE brand and logo are trademarks of the General Electric Company. © 2012 GE Lighting Solutions, LLC. Information provided is subject to change without notice. All values are design or typical values when measured under laboratory conditions.