5 Development Platform Quick Start
5.1 Tools Setup Sequence
Start the debugging system in the following sequence:
Connect a BGMA to the PC with a USB cable, confirm whether the LED on the BGMA is
green;
Connect an EV-board to BGMA IDC10 socket;
Select the EV-board power supply and turn on the EV-board, confirm whether the LED
on the BGMA is orange and the Power LED on the EV-board is on.
5.2 Open Project and Start Debug
Users can start a debug from a PC software SOFTUNE workbench in the following
sequence. Take SIMULATE LCD EVBOARD project as an example.
Start the SOFTUNE by selecting Programs> SOFTUNE V3> FFMC-8L Family
SOFTUNE Workbench from Start Menu.
Click Open workspace from File Menu in SOFTUNE;
Select SIMULATE LCD EVBOARD.wsp in Open Space window;
Click Start debug from Debug Menu.
If the entire procedure goes right, a debug will start normally.
5.3 Operation Precautions
All pins of MB95350L Series MCU are connected to Testing Pin on the EV-board. If user
wants to test the performance of a single pin, please connect it to the test pin.
Note: before connecting with BGMA, do not power on system.
It's recommended that only one power supply is used as a power module input at a time.
MB2146-460-E Setup Guide V1.2
Chapter 5 Development Platform Quick Start
MCU-AN-500083-E-12 – Page 51