ABB Z-MT Commissioning And Calibration Procedures page 9

Table of Contents

Advertisement

Flashing
Fuel 1 – – – – – – – –
or
Enter
Flashing
Fuel 1 – – – – – – – –
Enter
Flashing
Fuel 1 – – – – – – – –
Enter
From
Fuel ? xxxxxxxx xx
CO
constant
& ENT
2
or
Enter
H
0 constant
& ENT
2
or
Enter
Ef'ncy const
& ENT
or
Enter
Flashing
Fuel 2 – – – – – – – –
o r
Cell T/C?
yes
& ENT
Continued from opposite page.
Special Fuel 1 Name
(dual fuel versions only)
Any 8-character name can be programmed for the special fuel.
Set the first character of fuel 1 name (upper or lower case letters, numbers 0 to
9 and spare).
Store and advance to next letter.
Set the second character of fuel 1 name.
Store and advance to next letter.
Repeat for remaining characters.
Store.
Advance to next parameter.
Carbon Dioxide Constant
Set the required constant for the fuel used.
Store.
Advance to next parameter.
Water Constant
Set the required constant for the fuel used.
Store.
Advance to next parameter.
Efficiency Constant
Set the required constant for the fuel used.
Store.
Advance to next parameter.
Fuel 2 Type (dual fuel versions only)
Repeat the procedure as for Fuel Type (fuel 1 type, fuel versions)
Cell Thermocouple (single and dual fuel versions)
See overleaf.
Advance to next parameter.
Continued overleaf.
, above.
7

Advertisement

Table of Contents
loading

Table of Contents