(3)
Jog operation from PU
Enable the JOG operation mode using the operation panel and PU (FR-PU07) under speed control. Operation is
performed only while the start button is pressed.
Operation
1.
Confirmation of the operation status indicator and
operation mode indicator
The monitor mode should have been selected.
The drive unit should be at a stop.
2.
Press
to choose the PU Jog operation
mode.
3.
Press
.
While
is pressed, the motor rotates.
The motor runs at 150r/min. (Pr.15 initial value)
4.
Release
[When changing the speed of PU Jog operation]
5.
Press
to choose the parameter setting
mode.
6.
Turn
until Pr.15 Jog speed setting appears.
7.
Press
to show the currently set value.
(150r/min)
8.
Turn
to set the value to "
(300r/min)
9.
Press
to set.
10.
Perform the operations in steps 1 to 4.
The motor rotates at 300r/min.
Drive unit
R/L1
Three-phase AC
S/L2
power supply
T/L3
Operation panel
Hold down.
Release
".
Flicker...Parameter setting complete!!
Speed setting by external terminals
U
V
Motor
W
Display
STOP
PRM indicator is lit.
(The parameter number read previously
appears.)