Connectable components
9.2 PP 72/48D PN
1
on
off
on
off
on
off
on
off
NOTICE
A newly set PROFINET address will only come into effect after power OFF/ON.
See also
PROFINET cables (Page 57)
9.2.3.4

X111, X222 and X333 digital inputs/outputs

Cable specification
● Connectors: 50-pin ribbon cable connectors
● The required connecting cables (ribbon cables) must be provided by the user
● Max. cable length: 30 m
104
2
3
4
5
on
on
off
off
on
on
off
off
off
on
off
off
off
on
off
off
on
off
off
off
on
off
off
off
off
off
off
off
off
off
off
off
50-pin insulation displacement connectors with cable grip, ribbon cables and terminal
converters
are required for connecting digital inputs and outputs.
6
7
8
9
10
off
off
off
off
off
off
off
off
off
off
off
off
off
off
off
off
off
off
off
off
off
off
off
off
Default device name
pp72x48pn7
pp72x48pn6
pp72x48pn5
pp72x48pn4
pp72x48pn3
pp72x48pn2
pp72x48pn1
pp72x48pn
Manual, 09/2011, 6FC5397-1EP40-0BA0
.
NCU 7x0.3 PN