Dell S6010-ON Installation Manual

Hide thumbs Also See for S6010-ON:
Table of Contents

Advertisement

Quick Links

S6010-ON Installation Guide
January 2019

Advertisement

Table of Contents
loading

Summary of Contents for Dell S6010-ON

  • Page 1 S6010-ON Installation Guide January 2019...
  • Page 2 A WARNING indicates a potential for property damage, personal injury, or death. © 2016 - 2019 Dell Inc. or its subsidiaries. All rights reserved. Dell, EMC, and other trademarks are trademarks of Dell Inc. or its subsidiaries. Other trademarks may be trademarks of their respective owners.
  • Page 3: Table Of Contents

    Important information..............................15 5 S6010–ON installation..........................16 Unpack the S6010–ON system............................16 Unpacking steps................................. 16 Ground lug and bracket installation..........................17 Install the Dell ReadyRails System..........................19 1U tool-less configuration............................19 Two-post flush-mount configuration........................20 Two-post center-mount configuration........................21 Four-post threaded configuration..........................22 1U two-post installation..............................23...
  • Page 4 USA Federal Communications Commission (FCC) Statement................40 European Union EMC Directive Conformance Statement..................41 Japan: VCCI Compliance for Class A Equipment....................41 Korean Certification of Compliance......................... 42 Safety Standards and Compliance Agency Certifications..................42 Electromagnetic Compatibility (EMC)........................43 Product Recycling and Disposal..........................43 10 Dell support..............................45 Contents...
  • Page 5: About This Guide

    When no cable is connected, visible and invisible laser radiation may be emitted from the aperture of the optical transceiver ports. Avoid exposure to laser radiation and do not stare into open apertures. Related documents For more information about the S6010-ON system, see the following documents: • Dell Networking Release Notes for the S6010-ON System •...
  • Page 6: S6010-On System

    • S6010–ON Configurations Introduction The Dell S6010–ON is a top-of-rack (ToR) switch/router product for copper connections to 10 Gbps servers and 40 Gbps optical uplinks to the 40 Gbps switching fabric in the core. The S6010–ON offers the following features: •...
  • Page 7: Physical Dimensions

    Thirty–two 40 Gbps QSFP+ ports Stack ID USB Type A storage 10/100/1000BaseT Ethernet management port Luggage tag Figure 3. S6010–ON PSU-side view Five fan modules Power supply unit (PSU) Physical dimensions The S6010–ON has the following physical dimensions: • 434 x 460 x 43.5 mm (W x D x H) •...
  • Page 8: Luggage Tag

    Luggage tag The S6010-ON system has a pull-out tag. known as a luggage tag, on the I/O-side of the system. Figure 4. S6010-ON luggage tag Service tag PPID MAC address Express service code System status You can view system status information using the light emitting diodes (LEDs).
  • Page 9: Led Behavior

    LED behavior The following system LED behavior is seen during open networking installation environment (ONIE) operations: Figure 5. S6010–ON I/O side LEDs Master LED Status LED Locator LED RS–232/RJ-45 Serial Console Port LED QSFP+ LEDs Stack ID LED Management Port Link LED Fan LED Power LED Table 1.
  • Page 10 Description • Blinking amber one second on/one second off—port locator function QSFP+ port when used as four ports of 10G. All four LEDs are used. • Off—No Link • Solid amber—4x10G speed • Blinking amber—port activity at 4x10G speed • Blinking amber one second on/one second off—port locator function Displays the stack unit number of the switch...
  • Page 11: Prerequisite

    GND lug and screws for rack • Ground wire • Crimping tool • Anti-oxidant compound—Dell recommends NOALOX 4 or equivalent • Thread-locker compound—Dell recommends Threadlocker Blue 242 or equivalent • #1 and #2 Phillips screwdrivers • Torx screwdriver • Copper/fiber cables Other optional components are: •...
  • Page 12: Site Preparations

    Data centers. • Other locations where the National Electric Code (NEC) applies. For more information about S6010–ON specifications, see Specifications. NOTE: Install the S6010-ON system into a rack or cabinet before installing any optional components. Topics: • Site selection •...
  • Page 13: Cabinet Placement

    Ensure that the cabling is safely away from other devices that might damage the cables. If needed, allow one rack unit (RU) space between devices to provide room for cabling. • Positioned in a rack or cabinet, or on a desktop with adequate space in the front, back, and sides of the S6010-ON for proper ventilation and access. •...
  • Page 14: Fans And Airflow

    When you install two systems near each other, position the two chassis at least 5 inches (12.7 cm) apart to permit proper airflow. The fan speed increases when the internal temperature reaches 161.6°F (72°C) and decreases to normal speed when the temperature falls to 136.4°F (58°C). The S6010-ON never intentionally turns off the fans. Power To connect the chassis to the applicable power source, use the appropriate power cord.
  • Page 15: Nebs Compliance

    OSP wiring. WARNING: If you install and connect the S6010-ON system to a commercial AC power source, you must connect the system to an external special protection device (SPD). To be NEBs compliant: •...
  • Page 16: S6010-On Installation

    S6010–ON installation To install the S6010–ON system, Dell recommends completing the installation procedures in the order presented in this guide. Always handle the S6010–ON and its components with care. Avoid dropping the system or its field replaceable units (FRUs). NOTE: ESD damage can occur if components are mishandled.
  • Page 17: Ground Lug And Bracket Installation

    • A crimping tool • A thread-locker compound—Dell recommends Threadlocker Blue 242 or equivalent Attach the end of the ground wire to the GND lug: Coat the bare end of the wire with an anti-oxidant compound. b Insert the end of the wire into the lug.
  • Page 18 Attach the assembly to the S6010-ON chassis. Apply the thread-locker compound to the two pan head screws. b Attach the GND lug and bracket assembly to the two-hole chassis ground connector nuts on the S6010-ON PSU side, tightening the screws to ensure torque between 3–5 inch/lbs.
  • Page 19: Install The Dell Readyrails System

    The ReadyRails rack mounting system is provided to easily configure your rack so that you can install your switch. The Dell ReadyRails™ system is provided for 1U front-rack and two-post installations. The ReadyRails system includes two separately packaged rail assemblies and two rails that are shipped attached to the sides of the switch. Install the ReadyRails system using the 1U tool- less method or one of three possible 1U tooled methods (two-post flush mount, two-post center mount, or four-post threaded).
  • Page 20: Two-Post Flush-Mount Configuration

    Align and seat the back flange rail pegs in the back vertical post flange. To see how the pegs appear in both the square and unthreaded round holes, see item 1. Align and seat the front flange pegs in the holes on the front side of the vertical post. Repeat this procedure for the second rail.
  • Page 21: Two-Post Center-Mount Configuration

    Figure 11. Two-post flush-mount configuration Two-post center-mount configuration CAUTION: Your system is not NEBS Earthquake Z4-compliant if you use this installation method. Slide the plunger bracket rearward until it clicks into place and secure the bracket to the front post flange with two user-supplied screws, item 1.
  • Page 22: Four-Post Threaded Configuration

    Figure 12. Two-post center-mount configuration Four-post threaded configuration CAUTION: To be NEBS Earthquake Z4-compliant, you must remove the tool-less latch castings described in Step 1. Remove the latch castings from each end of the ReadyRails assemblies. Use a Torx driver to remove the two screws from each latch casting and remove each casting, item 1. Retain the castings for future rack requirements.
  • Page 23: 1U Two-Post Installation

    Figure 13. Four-post threaded configuration 1U two-post installation You can install the switch in a 1U flush or center two-post configurations. Slide the system into the rails in the same manner as the four- post configurations. 1U front-rack installation Configure the rails that are attached to the system. Attach the switch inner chassis member rails to the system, items 1 and 2.
  • Page 24 Figure 14. Switch rails attachment After you have installed both switch rails, line them up on the previously mounted ReadyRails and slide the switch in, item 1. Approximately 3 inches before you fully insert your system, the rail locking feature engages to keep the switch from inadvertently sliding out of the rack and falling, items 2 and 3.
  • Page 25: Ground Wire Installation

    Figure 15. Front-rack configuration installation Ground wire installation After you have installed the S6010-ON switch in a rack, complete the installation of the ground wire. You previously installed the GND lug and bracket assembly, with ground wire attached, to the chassis, see...
  • Page 26: Sfp+ And Qsfp+ Optic Installation

    S6010–ON ports include 32 ports that function either as 40 GbE, or, using breakout cables, as a configuration of 96 ports of 10 GbE SFP+. The 32 ports also include eight, ports 13–20, that are 40 GbE QSFP+. For a list of supported optics, see the S6010-ON Specification Sheet at www.dell.com/support/ or contact your Dell representative.
  • Page 27: Optic Removal

    Do not jerk or tug repeatedly on the tab. System power-up Supply power to the S6010-ON after it is mounted in a rack or cabinet. Dell recommends reinspecting your system before powering up. Verify the following: •...
  • Page 28 ONIE: Diag ONIE Run Diagnostic package for S6010-ON During initial setup, the system boots to ONIE Install. ONIE Install boots with ONIE Discovery to the console, ONIE:. To configure your system, see your third-party ONIE-compatible OS or Dell OS documentation. S6010–ON installation...
  • Page 29: Power Supplies

    The S6010–ON does not support mixing PSU types. You cannot replace an AC PSU with a DC PSU and you cannot replace an AC-R PSU with a DC-R PSU. NOTE: If you use a single PSU, install a blank plate in the other PSU slot. Dell recommends using power supply 1 (PSU1) as the blank plate slot. NOTE: ESD damage can occur if components are mishandled.
  • Page 30: Ac Power Supply Installation

    PSU and the status LED is at the bottom of the PSU. NOTE: If you use a single PSU, install a blank plate in the other PSU slot. Dell recommends using power supply 1, PSU1, as the blank plate slot.
  • Page 31: Ac Power Supply Replacement

    Dell Support. NOTE: If you use a single PSU, install a blank plate in the other PSU slot. Dell recommends using power supply 1 (PSU1) as the blank plate slot. Disconnect the power cable from the PSU. Use the grab handle to slide the PSU out of the power supply bay.
  • Page 32 Figure 19. DC power supply and connector cable DC PSU power socket Cable connector with thumb screws Cable connector wires Wiring block DC power source wires Strip 1/2 inches of insulation from each of the site’s DC power source black, green, and blue wires, item 5. Insert each of the site’s DC power source’s bare wire lengths into the wiring block, matching wire colors, items 3 and 4.
  • Page 33: Fans

    Fans The S6010–ON comes from the factory with two PSUs and five fan modules installed in the chassis. The fan modules and the integrated fan-power supply are hot-swappable. NOTE: To run the system, both slots must have operating fan units. If you do not install a module in each slot, either as part of the PSU or as an independent fan module, the system shuts down in one minute.
  • Page 34: Fan Module Installation

    Figure 20. AC PSU with one module Fan modules PSU 0 with integrated fan PSU 1 with slot cover Fan module installation The fan modules in the S6010–ON are field replaceable. Module slot 0 is on the left side of the chassis; module slot 1 is on the right side of the chassis. CAUTION: DO NOT mix airflow directions.
  • Page 35 The fan air filter media slides into the frame from the top. No tools are required. Determine which filters to replace. Unlatch and remove the first module that needs the filter replaced. Slide the existing filter upwards to remove it from the module. Replace the filter with a new filter of the same size.
  • Page 36: Management Ports

    Management ports Besides the 10 Gbps and 40 Gbps switch ports, the S6010–ON provides several ports for management and storage. Topics: • RS-232 console port access • Micro USB-B console port access • USB storage mount RS-232 console port access The RS-232 console port is on the I/O side of the S6010–ON chassis.
  • Page 37: Micro Usb-B Console Port Access

    The Micro USB-B console port is to the left of the RS-232/RJ-45 console port on the I/O side of the switch. NOTE: The S6010-ON switch uses the Silicon Labs CP2109 USB-B chip. To find the correct USB-B universal asynchronous receiver-transmitter (UART) driver, see https://www.silabs.com/products/development-tools/software/usb-to-uart-bridge-vcp-...
  • Page 38 For USB storage: Disk /dev/sdb: 30.9 GB, 30942946304 bytes 64 heads, 32 sectors/track, 29509 cylinders Units = cylinders of 2048 * 512 = 1048576 bytes Device Boot Start Blocks Id System Mount the device /dev/sdb to the /mnt/usb directory. ONIE:/ # mount -t vfat /dev/sdb /mnt/usb NOTE: The following message displays if the /mnt/usb directory is missing: mount: mounting /dev/sdb on /mnt/usb failed: No such file or directory.
  • Page 39: Specifications

    Specifications This chapter lists the S6010–ON specifications. CAUTION: Operate the product at an ambient temperature not higher than 113°F (45°C). CAUTION: Lithium Battery Caution: There is a danger of explosion if the battery is incorrectly replaced. Replace only with same or equivalent type of battery.
  • Page 40: Ieee Standards

    Properly shielded and grounded cables and connectors must be used in order to meet FCC emission limits. Dell Networking is not responsible for any radio or television interference caused by using other than recommended cables and connectors or by unauthorized changes or modifications in the equipment.
  • Page 41: European Union Emc Directive Conformance Statement

    Figure 23. Japan: VCCI Compliance for Class A Equipment WARNING: Use the AC power cords with Dell Networking equipment only. Do not use Dell Networking AC power cords with any unauthorized hardware. This is Class A product based on the standard of the Voluntary Control Council For Interference by Information Technology Equipment (VCCI).
  • Page 42: Korean Certification Of Compliance

    Korean Certification of Compliance Figure 25. Korean Certification of Compliance Figure 26. Korean Package Label Safety Standards and Compliance Agency Certifications • CUS UL 60950-1, 2nd Edition • CSA 60950-1-03, 2nd Edition • EN 60950-1, 2nd Edition • EN 60825-1, 1st Edition •...
  • Page 43: Electromagnetic Compatibility (Emc)

    You must recycle or discard this system according to applicable local and national regulations. Dell Networking encourages owners of information technology (IT) equipment to responsibly recycle their equipment when it is no longer needed. Dell Networking offers a variety of product return programs and services in several countries to assist equipment owners in recycling their IT products.
  • Page 44 WEEE. Customer participation is important to minimize any potential effects of EEE on the environment and human health due to the potential presence of hazardous substances in EEE. Dell Networking products, which fall within the scope of the WEEE, are labeled with the crossed-out wheelie-bin symbol, as shown above, as required by WEEE.
  • Page 45: Dell Support

    Dell support The Dell support site provides a range of documents and tools to assist you with using Dell equipment and mitigating the impact of network outages. Through the support site you can obtain technical information regarding Dell products, access software upgrades and patches, download available management software, and manage your open cases.
  • Page 46 Figure 28. S6010-ON luggage tag Service tag PPID MAC address Express service code Dell support...