Summary of Contents for Siemens CB15

  • Page 1 CB15/CB155 PROFIBUS Module...
  • Page 2: Table Of Contents

    5.1.3 Watchdog Timeout Settings on the PROFIBUS-DP Master 5.2.1 Setting the PPO Type from the Master 5.2.2 Setting the PPO Type on the CB15/CB155 Initial Communication with the CB15/CB155 6. PROFIBUS TROUBLESHOOTING Diagnostic Parameters Diagnostics with a Class 2 Master...
  • Page 3 PROFIBUS MODULE (CB15/CB155) English Operating Instructions Figures User Data Structure in the PROFIBUS-DP Message Frame Structure of the User Data in the PROFIBUS-DP Message Frame Parameter Process Data Object (PPO Types) Structure of the Parameter Area Parameter Identifier Example Parameter Value Example...
  • Page 4: Warning And Caution Notes

    PROFIBUS MODULE (CB15/CB155) English Operating Instructions Warning and Caution Notes WARNING Hazardous voltages are present in this electrical equipment during operation. Non-observance of the safety instructions can result in severe personal injury or death. Only qualified personnel should work on or around this equipment after becoming thoroughly familiar with all warnings, safety notices and maintenance procedures contained herein.
  • Page 5: Overview

    Operating Instructions 1. OVERVIEW 1.1 Description and Features The PROFIBUS Module (CB15/CB155) is a device that allows control of an inverter over a PROFIBUS-DP (SINEC L2-DP) serial bus. Features Retains the ability to access the internal parameter set of the inverter (CB15 only).
  • Page 6 Each word in the frame is assigned a fixed function. The CB15/CB155 supports the PROFIBUS-DP control commands FREEZE and SYNC. A diagnostics parameter can be used to read detailed diagnostics information straight from the diagnostics memory...
  • Page 7: Installation

    2.1.1 CB15 Installation Fix the CB15 to the front of the inverter by mating the D-type connectors together and then securing in position by pressing the module onto the inverter.
  • Page 8: Connecting The Bus Cable

    Diagram showing typical PROFIBUS installation using CB155 and COMBIMASTER 2.2 Connecting the Bus Cable 2.2.1 Terminals 2.2.1.1 CB15 Terminals The PROFIBUS connection must be made using the D-type socket on the front of the CB15. Connections to this socket are as follows: Pin 3 PROFIBUS P connection...
  • Page 9: Cb155 Terminals

    PROFIBUS MODULE (CB15/CB155) English Operating Instructions 2.2.1.2 CB155 Terminals The PROFIBUS connection will normally be made using the optional T connector 6SE9996-0XA21 ). This is connected to the free connector on the side of the CB155, and is in turn screwed to the front of the CB155, thus providing the PROFIBUS IN and OUT connections.
  • Page 10: Emc Measures

    The bus terminators must be connected to the first station (e.g. the master) and the last station (slave). For the CB15, this is achieved by moving the switch mounted on the D-type of the PROFIBUS-DP connector to the ON position.
  • Page 11: Front Panel

    PROFIBUS MODULE (CB15/CB155) English Operating Instructions 2.5 FRONT PANEL Figure 2: CB15 Front Panel...
  • Page 12: Operating Information

    3.3.2 for details) . 3.3 System Parameters The basic parameter set used by the CB15/CB155 is identical to that used for the inverter. However, some parameters cannot be accessed because either they are not required or they have been replaced by PROFIBUS parameters.
  • Page 13: Hex Display For Profibus On Cb15

    Set to ‘0’ and then press P to reset all parameters except P101 to the settings factory default settings. 3.3.3 Hex Display for PROFIBUS on CB15 Several PROFIBUS-DP parameters are displayed in hex format using the four digit 7-segment display on the inverter.
  • Page 14: Fault Codes

    4. FAULT CODES Fault codes are displayed and acknowledged for the CB15/CB155 in the same way as on the inverter. Several new error codes specific to PROFIBUS have been added and are described below. Further help may be found in section 5 (PROFIBUS Commissioning) and section 6 (PROFIBUS Troubleshooting).
  • Page 15: Commissioning

    Parameter identifier IND: Index PWE: Parameter value STW1: Control word 1 ZSW1: Status word 1 HSW: Main setpoint HIW: Main actual value Figure 3: Parameter Process Data Object (PPO Types) Note The CB15/CB155 only supports PPO types 1 and 3.
  • Page 16: Structure Of The Parameter Area

    Bits 0 to 10 contain the number of the desired parameter (PNU). Refer to section 4 of the instruction manual for the inverter. Bit 11 is the toggle bit for spontaneous messages. The CB15/CB155 does not support this function! Bits 12 to 15 contain the task or reply identifier (AK).
  • Page 17: Parameter Identifier Example

    PROFIBUS MODULE (CB15/CB155) English Operating Instructions Transmit number of array elements Task not executable (with error number) No exclusive use of PKW interface Reply Identifiers (Inverter _ Master) Error Meaning Number No reply Parameter value cannot be changed Lower or upper value limit exceeded...
  • Page 18: Parameter Value Example

    PROFIBUS MODULE (CB15/CB155) English Operating Instructions Parameter Value (PWE) (3rd and 4th Word) The parameter value (PWE) is always transmitted as a double word (32 bits). Only one parameter value can be transmitted in a frame. A 32-bit parameter value is composed of PWE1 (most significant word, 3rd word) and PWE2 (least significant word, 4th word).
  • Page 19: Process Data Area (Pzd)

    Fault message is acknowledged on positive edge, inverter subsequently switches to ‘start disable’. No meaning Jog clockwise CB15/CB155: Jog clockwise (only in conjunction with bit 0). No jog Jog counter-clockwise CB15/CB155: Jog counter-clockwise (only in conjunction with bit 0). No jog...
  • Page 20 PROFIBUS MODULE (CB15/CB155) English Operating Instructions PZD valid The process data transmitted by the master is valid. PZD invalid The process data transmitted by the master is invalid. free free free Rotate clockwise On/clockwise Rotate counter-clockwise On/counter-clockwise free...
  • Page 21: Status Word (Zsw

    PROFIBUS MODULE (CB15/CB155) English Operating Instructions 5.1.2.2 Status Word (ZSW) The status word matches the definition in the PROFIBUS ‘variable speed drives’ profile |3|. Slave -> Master Bit No. 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0...
  • Page 22: Watchdog Timeout

    (see section 5.1.2.3) . 5.1.3 Watchdog Timeout When communication starts, the PROFIBUS-DP master transmits a value t WD to the CB15/CB155 for the watchdog. The watchdog on the unit is activated or deactivated according to the transmitted value. When the watchdog is active, the CB15/CB155 monitors communication with the PROFIBUS-DP master.
  • Page 23: Settings On The Profibus-Dp Master

    The bus baud rate must not exceed 12 MBd. The inverter must be switched on. The slave address for the CB15/CB155 (parameter P918) must be set to match the slave address configured at the PROFIBUS master and must be unique on the bus.
  • Page 24: Profibus Troubleshooting

    PROFIBUS link is not successful, check the causes listed for fault codes F030 and F033. 6.1 Diagnostic Parameters The CB15/CB155 stores diagnostics information in a diagnostics buffer for installation and service purposes. The diagnostics information can be read out with the indexed parameter P880.i (diagnostics).
  • Page 25 P880.11 (Counter: watchdog timeout) Is incremented when the watchdog time expires. P880.12 (Address of PROFIBUS master) Address of the PROFIBUS master which has configured the CB15/CB155. P880.13 (Slave status) Mirror of the software status: Software not yet initialised. CB15/CB155 awaiting PROFIBUS parameterisation.
  • Page 26: Diagnostics With A Class 2 Master

    COM ET 200 software are included in the COM ET 200 software manual. Note that the Class 2 master may also be used without the IM308B/C being enabled on the bus. The Class 2 master may also be connected directly to the D-type connector on the CB15/CB155 if desired. WARNING When using a Class 2 master to control a slave device, the PROFIBUS watchdog is not enabled.