Fujitsu BS2000 SE Series Operating Manual page 30

Server unit /390
Hide thumbs Also See for BS2000 SE Series:
Table of Contents

Advertisement

SVP frames and subframes
IPL DEVICE ==> By entering the corresponding number in this field you can specify from
1
2
3
PARMS =>
Position 1
Position 2
- 5
Position 6
- 8
30
which device group an IPL is to be executed.
PRESET GROUP
CURRENT GROUP
UNIT ADDRESS
A maximum of 8 characters can be entered in this field. Their position
and meaning are listed below:
loading BS2000
Ë
1
loading VM2000
mn The mnemonic pair of an SKP console can be entered here if the
standard consoles with the mnemonic pairs C2C3 and C4C5 are not
available for the IPL.
not used
Operating the service processor
The first device address in this column is the
device from which an IPL is to be executed. The
order and number were specified previously in
(AU5) AUXILIARY FRAME: LOAD PRESET-1.
If IPL is terminated normally, the device address
list is transferred from the PRESET GROUP to the
CURRENT GROUP.
If the IPL is unsuccessful, the next device address
from the PRESET GROUP is reloaded. If this
loading is terminated normally, this device address
heads the CURRENT GROUP.
The first device address in this column is the
device from which the last IPL was executed.
If the loading from this device is unsuccessful, the
IPL is repeated with the next device address. If it is
terminated normally, this address then heads the
CURRENT GROUP
A new device address from which the operating
system is to be loaded can be entered here. If the
IPL is terminated normally, this device address is
put in the first position in the CURRENT GROUP.
If the IPL is unsuccessful, the loading is not
repeated.