Checking The Level Of The Hydraulic Fluid - Toro GreensPro 1260 Greens Roller Operator's Manual

Serial no. 403316784 and up
Table of Contents

Advertisement

Figure 16
1.
Position the machine on a flat surface so that
the engine is level.
2.
Shut off the engine, wait for it to cool, and clean
the area around the oil-filler cap/dipstick
17).
Figure 17
1. Oil-filler cap/dipstick
3.
Remove the oil-filler cap/dipstick by rotating it
counterclockwise.
4.
Wipe the oil-filler cap/dipstick clean and insert it
into the filler port.
Note:
Do not screw the dipstick into the port.
5.
Remove the dipstick and check the oil level.
Note:
If the oil level is near or below the
lower-limit mark on the dipstick, add only enough
oil to raise level to the upper-limit mark (bottom
edge of the oil-fill hole); refer to
the oil level again. Do not overfill the crankcase.
g018667
(Figure
g024013
2. Filler port
Figure
18. Check
1. Upper limit
6.
Install the oil-filler cap/dipstick and wipe up any
spilled oil.
Note:
Running the engine with the oil level at the
lower limit may induce nuisance engine shutdowns in
operating situations where the machine is switching
direction on an incline or descent.
Checking the Level of the
Hydraulic Fluid
Service Interval: Before each use or daily
The hydraulic system is filled at the factory with
high-quality hydraulic fluid. Check the level of the
hydraulic fluid before the engine is first started
and daily thereafter.
Note:
Before working on any part of the hydraulic
drive system, shut off the engine to depressurize the
system. Before starting the engine after hydraulic
system maintenance, and pressurizing the hydraulic
lines, check all hoses and connectors for damage and
to ensure that they are tight. Replace any damaged
hoses and tighten any loose couplings as required.
Recommended Hydraulic Fluid: Toro Premium All
Season Hydraulic Fluid (Available in 5 US gallon
pails or 55 US gallon drums. Refer to the parts catalog
or contact your Authorized Toro Distributor for part
numbers.)
Alternative fluids: If the Toro fluid is not available,
other conventional, petroleum-based fluids may be
used, provided they meet all of the following material
properties and industry specifications. Check with
your oil supplier to see whether the oil meets these
specifications.
Note:
Toro will not assume responsibility for damage
caused by improper substitutions, so use only
products from reputable manufacturers who will stand
behind their recommendation.
15
Figure 18
2. Lower limit
g024239

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Greenspro 44913Greenspro 126044913

Table of Contents