Bosch Worcester Greenstore 180 Instruction Manual
Bosch Worcester Greenstore 180 Instruction Manual

Bosch Worcester Greenstore 180 Instruction Manual

Indirect unvented cylinder with solar coil

Advertisement

Quick Links

WORCESTER GREENSTORE
Indirect Unvented Cylinder with Solar Coil
FOR USE WITH WORCESTER GREENSTORE SYSTEM HEATPUMP ONLY
GB/IE
WORCESTER GREENSTORE 180 CYLINDER
SOLAR COMPATIBLE
WORCESTER GREENSTORE 280 CYLINDER
SOLAR COMPATIBLE

Advertisement

Table of Contents
loading

Summary of Contents for Bosch Worcester Greenstore 180

  • Page 1 WORCESTER GREENSTORE Indirect Unvented Cylinder with Solar Coil FOR USE WITH WORCESTER GREENSTORE SYSTEM HEATPUMP ONLY GB/IE WORCESTER GREENSTORE 180 CYLINDER SOLAR COMPATIBLE WORCESTER GREENSTORE 280 CYLINDER SOLAR COMPATIBLE...
  • Page 2: Storage Prior To Installation

    Bracket for (1 x manual reset - high limit stat for solar) Expansion Vessel • Installation & Maintenance Instructions • Hot water sensor GT3 (Supplied with cylinder) Acetal Solar High Installation & Tundish Limit Stat Maintenance Instructions INTRODUCTION Worcester Bosch Greenstore...
  • Page 3: Water Supply

    The pressure reducing valve, non return valve and expansion relief valve are combined together in the inlet control set. Consideration should be given for servicing and repair, when siting the cylinder. The cylinder position should be taken into consideration when siting the Heat Pump. Worcester Bosch Greenstore...
  • Page 4: General Installation

    3 bar and thus automatically balanced. The expansion relief valve section must still be mounted just above the TPRV on the cylinder. A 3/4”F-22mm compression adaptor will be needed (not supplied) Worcester Bosch Grrenstore GENERAL INSTALLATION...
  • Page 5: Discharge Arrangement

    27m 1.4m 28mm up to 9m 1.0m <G3>/4 22mm 35mm up to 18m 1.4m 42mm up to 27m 1.7m 35mm up to 9m 1.4m 28mm 42mm up to 18m 1.7m 54mm up to 27m 2.3m Worcester Bosch Greenstore DISCHARGE ARRANGEMENT...
  • Page 6: Commissioning Servicing

    PRIMARY CIRCUIT - INDIRECT UNITS a level well below the unit (The greater the difference in elevation, Consult the Worcester Bosch commissioning instructions and fill the greater the flow rate and the maximum amount of water drained the primary circuit.
  • Page 7: Technical Specifications

    Remove the cylinder front cover. Feed the sensor cable through the grommet of the right-hand cable entry, on top of the cylinder. Fully insert the sensor probe into the GT3 sensor pocket, as indicated on the diagram above. Replace the cylinder front cover. TECHNICAL SPECIFICATIONS Worcester Bosch Greenstore...
  • Page 8: Specification Summary

    180 L 1520 7 716 180 018 280 L 1700 All Dimensions are of the cased unit and are in mm. Approvals - KIWA Approved to the Water Regulations - KIWA Approved to Building Regulations’ G3 & L1 Worcester Bosch Greenstore...
  • Page 9: All Products

    HAVE YOU DEMONSTRATED THE OPERATION OF THE SYSTEM CONTROLS TO THE CUSTOMER? HAVE YOU LEFT ALL THE MANUFACTURER’S LITERATURE WITH THE CUSTOMER? COMPETENT PERSON’S CUSTOMER’S SIGNATURE SIGNATURE (To comfirm demonstations of equipment and receipt of appliance instructions) Worcester Bosch Greenstore...
  • Page 10: Service Provider

    TEL No. TEL No. CORGI ID SERIAL No. CORGI ID SERIAL No. COMMENTS COMMENTS SIGNATURE SIGNATURE When all the above service entries have been completed, please contact your Service Engineer for an additional sevice interval record sheet Worcester Bosch Greenstore...
  • Page 11 NOTES NOTES Worcester Bosch Greenstore...
  • Page 12: Contact Information

    WEBSITE: www.worcester-bosch.co.uk Worcester, Bosch Group, Cotswold Way, Warndon, Worcester WR4 9SW Tel. 01905 754624 Fax. 01905 754619 Worcester, Bosch Group is a brand of BBT Thermotechnology UK Ltd. www.worcester-bosch.co.uk User and Installation Instructions Greenstore Cylinder -Solar Compatible 8 716 113 377b 2007/01 EN...

Table of Contents