Toro Groundsmaster 3500-D Operator's Manual page 40

Hide thumbs Also See for Groundsmaster 3500-D:
Table of Contents

Advertisement

Servicing the Air-Cleaner Filter
Service Interval: Every 200 hours (More frequently in
extreme dusty or dirty conditions)
1.
Before removing the filter, use clean and dry,
low-pressure air (275 kPa or 40 psi) to help
remove large accumulations of debris packed
between the outside of the primary filter and the
canister.
Important:
Avoid using high-pressure air
that could force dirt through the filter and
into the intake tract, causing damage. This
cleaning process prevents debris from
migrating into the intake when you remove
the primary filter.
2.
Remove the primary filter
Important:
Do not clean the used element to
prevent the possibility of damaging the filter
media. Inspect the new filter for shipping
damage, checking the sealing end of the
filter and the body. Do not use a damaged
element.
Important:
Do not attempt to clean the
safety filter. Replace the safety filter after
every 3 primary-filter services
Figure 44
(Figure
45).
(Figure
1. Rubber outlet valve
2. Air-cleaner latch
3. Air cleaner primary filter
g031340
1. Safety filter
3.
Replace the primary filter
4.
Insert the new filter by applying pressure to the
outer rim of the element to seat it in the canister.
Note:
center of the filter.
5.
Clean the dirt-ejection port located in the
removable cover.
6.
Remove the rubber outlet valve from the cover,
clean the cavity, and replace the outlet valve.
7.
Install the cover, orienting the rubber outlet valve
in a downward position between the 5 o'clock to
7 o'clock positions when viewed from the end,
and secure the latch
46).
40
Figure 45
4. Air-cleaner body
5. Air-cleaner-restriction
sending unit
6. Rubber intake hose
Figure 46
(Figure
Do not apply pressure to the flexible
(Figure
45).
g032050
g008861
45).

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Groundsmaster 3505-d30849

Table of Contents