English Contents Contents _____________________________________________________________6 Introduction __________________________________________________________ 7 General description (Fig. A) ______________________________________________ 7 Intended use _________________________________________________________ 8 Important safety information ____________________________________________ 8 Contraindications ______________________________________________________ 8 Warning ______________________________________________________________9 Caution _____________________________________________________________ 10 Preparing for use _____________________________________________________ 10 Cleaning and sanitizing ________________________________________________ 10 Cleanable parts ______________________________________________________ 10 Disinfection (optional) __________________________________________________11 Find the best cushion for you ___________________________________________ 12...
Philips Avent offers, register your product at www.philips.com/welcome. The Philips Avent breast pump has a unique design that enables you to sit in a more comfortable position while expressing. The soft massage cushion* is designed to feel soft and warm and to mimic your baby’s suckling action to provide milk flow - comfortably and...
SCF334 contains: Twin electric breast pump (including bottle), breast pads (4), travel bag Intended use The Philips Avent Comfort Single/Twin electric breast pump is intended to express and collect milk from the breast of a lactating woman. The device is intended for a single user.
- Always switch off the breast pump before you remove the pump body from your breast to release the vacuum. - Never use any accessories or parts from other manufacturers or that Philips Avent does not specifically recommend. This could lead to improper working of the appliance and could influence Electromagnetic Compatibility (EMC).
English - If the process becomes very uncomfortable or painful, stop using the pump and consult your breastfeeding advisor. - If the pressure generated is uncomfortable or causes pain, switch off the appliance, break the seal between the breast and the pump body with your finger and remove the pump from your breast.
English Bottle parts: - Philips Avent Natural bottle - Dome cap - Screw ring - Teat - Sealing disc Accessories - Manual breast pump converter Handle Silicone diaphragm with stem Supplies needed for cleaning: Washing in sink Washing in dishwasher...
This can cause irreversible product deformation or damage that Philips cannot be held liable for. Allow water to cool and gently remove the parts from the water. Place the parts neatly on a clean paper towel or in a clean drying rack and allow them to air dry.
English 7 Press in between the petals to remove any trapped air (Fig. 12). Note: Place the cover over the cushion to keep the breast pump clean while you prepare for expressing. Warning: Always use the breast pump with a cushion. 8 Insert the adapter into the wall socket and insert the plug at the other end into the motor unit (Fig.
Using a breast pump requires practice and it may take several attempts before you succeed. Fortunately, the Philips Avent electric breast pump is easy to assemble and use so you will soon get used to expressing with it.
If you intend to feed your baby with the expressed breast milk within 48 hours, you can store the breast milk in the fridge in an assembled Philips Avent bottle or storage cup.
Philips dealer. You can also contact the Philips Consumer Care Center in your country. - Do not mix Philips Avent Anti-colic bottle parts and nipples with parts of the Philips Avent Natural bottles. They may not fit and could cause leakage or other issues.
English Cautions to avoid damage to the product: - Do not place in a heated oven, plastic can melt. - Plastic material properties may be affected by disinfection and high temperatures. This can affect the fit of the dome cap. - Do not leave a feeding nipple in direct sunlight or heat, or leave in disinfectant for longer than recommended because this may damage the product.
Over time, you can change the nipple to accomodate the individual needs of your baby. Choosing the right teat for your baby The Philips Avent teats are available with different flow rates to help your baby with drinking. Over time you can change the teat accommodating the individual needs of your baby. Philips Avent teats are clearly numbered on the side to indicate flow rate (see image).
4 Reattach the bottom to the motor unit. Ordering accessories To buy accessories or spare parts, visit www.shop.philips.com/service or go to your Philips dealer. You can also contact the Philips Consumer Care Center in your country (see the international warranty leaflet for contact details).
English Accessories Manual breast pump converter With the manual breast pump converter, you can assemble the manual breast pump. Before you use the manual breast pump, read the instructions for the electric breast pump (see chapter ‚Preparing for use‘, section ‚Using the breast pump‘). All instructions for the electric breast pump also apply to the manual breast pump converter, except the chapters „Assembling the breast pump“...
Note: If you regularly express more than 125ml per session, you can purchase and use a 260ml/9fl oz Philips Avent bottle to prevent overfilling and spillage. 9 When you have finished expressing, carefully remove the breast pump from your breast and unscrew the bottle or storage cup from the pump body.
English Warranty and support If you need information or support, please visit www.philips.com/support or read the international warranty leaflet. Troubleshooting This chapter summarizes the most common problems you could encounter with the appliance. If you are unable to solve the problem with the information below, visit www.philips.com/support for a list of frequently asked questions or contact the Consumer...
Follow below guidelines if you experience too much suction with suction. your breast pump:- Make sure you only use the Philips Avent comfort breast pump’s parts.- Make sure you have assembled the comfort breast pump with the massage cushion: not using the massage cushion can result in too much vacuum.- When...
Electromagnetic Compatibility (EMC, IEC 60601-1-2) Declaration – electromagnetic emissions The Philips Avent breast pump is intended for use in the electromagnetic environment specified below. The user of the Philips Avent breast pump should assure that it is used in such an environment. Emissions test Compliance Electromagnetic environment –...
Page 25
Note: UT is the a.c. mains voltage prior to application of the test level. Declaration – electromagnetic immunity The Philips Avent breast pump is intended for use in the electromagnetic environment specified below. The user of the Philips Avent breast pump should assure that it is used in such an environment.
Page 26
RF transmitters, an electromagnetic site survey should be considered. If the measured field strength in the location in which the Philips Avent breast pump is used exceeds the applicable RF compliance level above, the Philips Avent breast pump should be observed to verify normal operation.
English The Philips Avent breast pump is intended for use in a home healthcare environment in which radiated RF disturbances are not controlled The user of the Philips Avent breast pump can help prevent electromagnetic interference by maintaining a minimum distance between portable and mobile RF communications equipment (transmitters) and the Philips Avent breast pump as recommended below, according to the maximum output power of the communications equipment.
English Storage conditions Temperature -13°F (-25°C) to 158°F (70°C) Relative humidity 15% to 93% (non-condensing) Technical specifications The adapter is not a part of the medical electric equipment, but is a separate power supply within the medical electric system. Mains input Voltage: 100-240V Mains input Current: 1000mA...
Page 29
English Symbol for 'follow instructions for use'. Indicates the need for the user to consult the instructions for use for important cautionary information such as warnings and precautions that cannot, for a variety of reasons, be presented on the medical appliance itself. Indicates usage tips, additional information or a note.
Page 30
Indicates the manufacturer's serial number so that a specific medical appliance can be identified. EurAsian Conformity Mark Symbol for the 2 year Philips warranty. Battery powered (only for single electric breast pump) UL (Underwriters Laboratories) testing according to the household standard RCM Tick Mark–...