Basic construction type acc.
to rating plate
IM B3
IM B35 (1)
The maximum permissible speed for flange-mounted construction types (IM B5, IM V1, IM
V3) is restricted to 3000 rpm (see also "Planning Guide").
Note
For additional instructions and restrictions for construction types that do not correspond to
the basic type, please refer to the "Planning Guide".
Additional hoisting points for different construction types (option)
Additional hoisting points are provided for those construction types that differ from the basic
construction types IM B3 and IM B35 (see Fig.).
Figure 2-3
①
[ID: 318.01]
2.5.4
Regulations
Overview
The motors comply with the following regulations under IEC EN 60034:
A5E00215731A AD
Siemens AG Operating Instructions 2.02 1PL618
Type
1PL6 184...1PL6 186
1PL6 184...1PL6 186
View from above onto construction type IM B3
Hoisting points
Other applications in construction type
IM B6, IM B7, IM B8, IM V5, IM V6
IM V36, IM V15
Description
2.5 Layout
19