Specifications
Power supply
Display
Measurement method Oscillometric method
Measurement range
Accuracy
Normal operating
conditions
Storage and trans
portation conditions
Measurement perime
ter of the wrist
Net weight
External dimensions
Accessories
Mode of operation
Degree of protection
Protection against
ingress of water
Device classification
Caution: No modification of this equipment is
allowed.
Electromagnetic emissions
and immunity
The device is approved according to EMC safety
standard EN 60601-1-2. It is designed to be used in
typical domestic environments.
EMC Guidance
- The Blood Pressure Monitor needs special pre
cautions regarding EMC and needs to be
installed and put into service according to the
EMC information provided in the accompanying
documents.
- Wireless communications equipment such as
wireless home network devices, mobile phones,
cordless telephones and their base stations,
walkie-talkies can affect this equipment and
should be kept at least a distance d = 3.3 m
away from the equipment.
Note: As indicated in IEC 60601-1-2:2007 for ME
equipment, a typical cell phone with a maximum
output power of 2 W yields d = 3.3 m at an immuni
ty level of 3V/m.
Guidance and manufacturer's declara
tion – electromagnetic emissions - for
all ME equipment and ME systems
Guidance and manufacturer's declaration – elec
tromagnetic emissions
The device is intended for use in the electromag
netic environment specified below. The customer
or the user of the device should assure that it is
used in such an environment.
Emissions test
RF emissions
CISPR 11
RF emissions
CISPR 11
Harmonic emis
sions IEC
61000-3-2
Voltage fluctua
tions/flicker
emissions IEC
61000-3-3
Guidance and manufacturer's declara
tion – electromagnetic immunity – for
all ME equipment and ME systems
Guidance and manufacturer's declaration – elec
tromagnetic immunity
The device is intended for use in the electromag
netic environment specified below. The customer
3.7V 420mAH built-in
rechargeable li-polymer
battery
Display with white back
light
Visible area = 46.8mm (L)
x29.3mm (W)
Rated cuff pressure:
0kPa-40kPa
(0mmHg-300mmHg)
Measurement pressure:
4kPa-34kPa
(40mmHg-230mmHg)
heart rate: 40-199 beats
per minute
Pressure:
5°C-40°C with
in ±0.4kPa (±3mmHg)
heart rate:±5% of mea
surement result on dis
play
Temperature: 5°C to
40°C. Relative humidity:
≤85%RH. Atmospheric
pressure: 86kPa to
106kPa
Temperature: -20°C to
60°C. Relative humidity:
10% to 93%. Atmospheric
pressure: 50kPa to
106kPa
About 13.5cm-21.5cm
Approx. 100g
Approx.
80mm×65mm×13.2mm
USB cable, user manual
Continuous operation
Type BF applied part
IP22, This means: pro
tected against access to
hazardous parts with a
finger and against verti
cally falling water drops
when tilted up to 15
degrees.
Battery Powered Mode:
Internally Powered ME
Equipment. Class II ME
Equipment
Com
Electromagnetic
pliance
environment - guid
ance
Group
The device must emit
2
electromagnetic
energy in order to
perform its intended
function. Nearby
electronic equipment
may be affected.
Class B
Not
applica
ble
Not
applica
ble