Table 2
Aquarea Duo Pre-Plumbed
Product Stock Code
Energy efficiency class
Heat loss
Capacity - total volume
Volume heated by IH
Weight - empty/full
Pressure regulating valve setting
Expansion relief valve setting
Temperature setting (P&T valve)
Pressure setting (P&T valve)
Expansion vessel size (volume)
Expansion vessel initial charge pressure
Height
Diameter
Buffer vent
Buffer connections
Cold feed
Hot supply
Tundish
Secondary return
Heat pump flow
Control thermostat (x2)
Immersion heater
Heat pump return
Primary heat exchanger surface area
Primary heat exchanger thermal rating
Primary heat exchanger pressure loss
Heat up time from 15°C to 50°C
Average domestic hot water
temperature
1
1. Measured at 0.25 l/s primary flow rate
NOTES
1. Recovery times base on Primary Coil/I.H. duty (ie. assumes the heat pump output is adequate).
GH 200/70L PP Heat Pump Buffer
watts
litres
litres
kg
bar
bar
°C
bar
litres
bar
mm
mm
A
mm
B
mm
C
mm
D
mm
E
mm
F
mm
G
mm
H
mm
J
mm
K
mm
m
1
2
1
kW
1
bar
2
min
°C
2. Measured at 0.25 l/s primary flow rate and at 55°C flow temperature
PAW-TE20BUF70PRE-UK
ASLPAN200HP3SQM70BUFPP
C
84
210
199
57/327
3
4.5
95
6.0
24
3
1992
550
2000
1657
1110
1190
690
1127
963
495
220
390
3
17.91
0.032
20.47
46.77
Buffer CH Flow 60°
Buffer CH Return 40°
Cold Feed 25°
Buffer Inspection Port 20°
T & P Relief Valve 7.5°
Buffer Stat Pocket
Cylinder Stat Pocket
Immersion Heater
TECHNICAL INFORMATION
Page 5
DESIGN
GH 300/70L PP Heat Pump Buffer
PAW-TE30BUF70PRE-UK
ASLPAN300HP3SQM70BUFPP
D
109
300
279
61/431
3
4.5
95
6.0
35
3
2030
630
2037
1752
1205
1330
825
1170
1000
560
240
433
3
13.18
0.032
42.5
42.06
Secondary Return 57.5°
Hot Supply 52.5°
Buffer HP Flow 35°
Cylinder HP Flow & Return 35°
2nd Cylinder Stat Pocket 27.5°
Buffer HP Return 15°