200 Engine and cooling system
Removal and installation of hydraulic oil cooler assembly
12. Move cover (9).
13. Lift out hydraulic oil cooler assembly (10) by
using eyebolt (M10) [1].
4
Hydraulic oil cooler assembly: 25 kg
PC200, 200LC, 220, 220LC-8M0
Installation
q
Installation is done in the reverse order of re-
moval.
[*1]
a Confirm that the heat insulating seal material
(sponge) of the radiator peripheral part is not
damaged. If the heat insulating seal material
(sponge) is damaged, replace it to the new
one.
Confirm from the under cover side that convexity
(A) of the radiator is correctly set to concavity (B).
[*1]
Refilling with oil (hydraulic tank)
q
Refill hydraulic oil through the oil filler port to
the specified level. Let the oil circulate in the
hydraulic system by starting the engine. Then
check the oil level again.
SEN06143-00
39
50-200