A B B M E A S U R E M E N T & A N A LY T I C S | C O M M U N I C AT I O N S S U P P L E M E N T
AWT210
HART 2-wire transmitter
Introduction
AWT210
This Communication Supplement provides
2-Wire transmitter
procedures specifically related to the AWT210
HART® 2-wire transmitter. Refer to the AWT210
Operating Instruction (OI/AWT210-EN) for general
information on installation, operation and
maintenance.
Measurement made easy
For more information
Further publications for the AWT210 transmitter are
available for free download from:
www.abb.com/measurement
or by scanning this code:
AWT210 transmitter –
Data Sheet
AWT210 transmitter –
Commissioning Instruction
AWT210 transmitter –
Operating Instruction
AWT210 transmitter –
HART FDS Communications Supplement
Search for or click on:
DS/AWT210-EN
CI/AWT210-EN
OI/AWT210-EN
COM/AWT210/
HART/FDS-EN

Advertisement

Table of Contents
loading

Summary of Contents for ABB AWT210

  • Page 1 Measurement made easy Introduction For more information — AWT210 This Communication Supplement provides Further publications for the AWT210 transmitter are 2-Wire transmitter procedures specifically related to the AWT210 available for free download from: HART® 2-wire transmitter. Refer to the AWT210 www.abb.com/measurement...
  • Page 2: Table Of Contents

    Universal HART commands ....9 AWT210 transmitter – electrical....3 Common practice HART commands.
  • Page 3: Health & Safety

    AW T 2 1 0 H A R T 2 - W I R E T R A N S M I T T E R | C O M/A W T 2 1 0/ H A R T- E N R E V. B Health & Safety Document symbols Potential safety hazards AWT210 transmitter – electrical Symbols that appear in this document are explained below: DANGER – SERIOUS DAMAGE TO HEALTH WARNING – BODILY INJURY...
  • Page 4: Waste Electrical And Electronic Equipment (Weee)

    Direct current supply only. manufacturer for disposal at no charge to the user. ABB is committed to ensuring that the risk of any This symbol, when noted on a product enclosure or environmental damage or pollution caused by any of barrier, indicates that a risk of electrical shock and/or its products is minimized as far as possible.
  • Page 5: Overview

    COM/AWT210/ AWT210 transmitter HART HART-FDS-EN Field Device Specification Four variants of AWT210 are available for use with pH, ORP, pIon, and conductivity sensors. HART manufacturing ID and device type The device has four dynamic variables. The device does not All HART products contain unique identifiers that specify the have any device variables.
  • Page 6: Transmitter Functionality And Operator

    Process Variable (detailed in commissioning instructions) and 5 location installation requirements refer to the to 8 for temperature sensor (up to 3 wire RTD + shield). AWT210 Operating Instructions (OI/AWT210-EN). Operating ranges correspond to the capabilities of each sensor • The signal/power terminals accept wire sizes type.
  • Page 7: Analog Mode Signal And Power Wiring

    Do not connect secondary communication device directly across the power supply. Load resistance must include any meters external to the AWT210 transmitter, the wiring and the system input. IMPORTANT (NOTE) The equation for minimum supply voltage is based on a maximum output current of 20 mA. In some cases such as fail high or process variable over range –...
  • Page 8: Multi-Drop Mode (Digital) Signal And Power Wiring

    Each transmitter on the bus is wired from the primary communication device to the positive (+) and negative (–) IMPORTANT (NOTE) POWER (SIGNAL) terminals of the AWT210. Connect all Only one secondary device can communicate on the transmitters on the bus in parallel.
  • Page 9: Appendix

    Read Board Object Write Object Device-specific command details such as data bytes and Read Memory response codes are described in the AWT210 HART field device Write Memory specification (COM/AWT210/HART-FDS-EN) Reset Software Write Protection Read Revision Supported HART commands...
  • Page 10: Device--Specific Hart Commands

    AW T 2 1 0 H A R T 2 - W I R E T R A N S M I T T E R | C O M/A W T 2 1 0/ H A R T- E N R E V. B …...
  • Page 11: Four Electrode Conductivity (Ec)

    AW T 2 1 0 H A R T 2 - W I R E T R A N S M I T T E R | C O M/A W T 2 1 0/ H A R T- E N R E V. B Device-specific HART commands: Device-specific HART commands: Four Electrode Conductivity (EC)
  • Page 12 We reserve the right to make technical changes or modify the contents of this document without prior notice. With regard to purchase orders, the agreed particulars shall prevail. ABB AG does not accept any responsibility whatsoever for potential errors or possible lack of information in this document.