GE ALPS Instruction Manual page 314

Advanced line protection system
Table of Contents

Advertisement

B.2 REGISTER MAPS
Table B–5: DATA FORMATS (Sheet 11 of 12)
TYPE
VALUE/
BITMASK
F61
139
ctd
140
B
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
166
167
168
169
170
171
172
173
B-20
DESCRIPTION
TRIP CIRCUIT #4 MONITOR
ALARM ON
TRIP CIRCUIT #4 MONITOR
ALARM OFF
TRIP CIRCUIT #5 MONITOR
ALARM ON
TRIP CIRCUIT #5 MONITOR
ALARM OFF
TRIP CIRCUIT #6 MONITOR
ALARM ON
TRIP CIRCUIT #6 MONITOR
ALARM OFF
PILOT PROTECTION ON
PILOT PROTECTION OFF
OSCILLOGRAPHY TRIGGERED
FAIL-TRIP BUS CHECK
UNBALANCED SYSTEM
DETECTION ALARM ON
UNBALANCED SYSTEM
DETECTION ALARM OFF
ZONE MEASUREMENT UNITS
ALARM ON
ZONE MEASUREMENT UNITS
ALARM OFF
OVERCURRENT MONITOR
ALARM ON
OVERCURRENT MONITOR
ALARM OFF
TRIP CIRCUIT #1 NOT
ENERGIZED
TRIP CIRCUIT #2 NOT
ENERGIZED
TRIP CIRCUIT #3 NOT
ENERGIZED
TRIP CIRCUIT #4 NOT
ENERGIZED
TRIP CIRCUIT #5 NOT
ENERGIZED
TRIP CIRCUIT #6 NOT
ENERGIZED
Recloser in Reset
Reclose In Progress - Start
Reclose In Progress - End
Single Pole Reclose - Shot1
Single Pole Reclose - Shot2
Single Pole Reclose - Shot3
Single Pole Reclose - Shot4
Three Pole Reclose - Shot1
Three Pole Reclose - Shot2
Three Pole Reclose - Shot3
Three Pole Reclose - Shot4
OUT OF STEP TRIP ON
OUT OF STEP TRIP OFF
ALPS Advanced Line Protection System
Table B–5: DATA FORMATS (Sheet 12 of 12)
TYPE
VALUE/
DESCRIPTION
BITMASK
F61
174
RUNTIME ANI CONTROL ERROR
ctd
175
RUNTIME ANI REFERENCE
ERROR
176
TOC Curve Changed
177
Run time DSP handshake
178
Run time DSP PROGRAM ROM
179
Run time DSP STATIC RAM
180
Run time DSP CRC STATIC RAM
181
Run time DSP DPRAM
182
Run time DSP DPRAM
CHECKSUM
183
Run time NO DMA interrupt
184
EEPROM CRC Recalculated
185
Max Breaker operations exceeded
186
Max I2T exceeded
187
No Sync Check
188
Recloser in Lockout - No Inhibit
Input
189
Recloser in Lockout - Breaker open
190
Recloser in Lockout - Reclose
Unsuccessful
191
Recloser in Lockout - Reclose
Cancel
192
Recloser in Lockout - Breaker Fail
to open
193
Recloser in Lockout - Maximum
Shots
194
Recloser in Lockout - Invalid
Reclose Type
195
Reclose - Output Issued
196
Recloser in Lockout - Manual
Lockout
F69
2 bytes
Event Source
0
Port PL1
1
Port PL2
2
Port PL3
3
LUI
4
Protection
5
Self Test
6
Start Up
P10
2 bytes
Integer Fixed Point, 1 Decimal
Field Value is multiplied by 10
P100
2 bytes
Integer Fixed Point, 2 Decimals
Field Value is multiplied by 100
APPENDIX B
GE Power Management