SELECTABLE WATTAGE HOT TANK OPERATING INSTRUCTIONS
1.Hot switch:
Turn On: It will turn Hot Tank ON.
Thermostat will control temperature.
Needed to be ON for Selectable Power
to work.
Turn OFF: Heating system stop working.
2.Cold switch:
Turn ON: It will turn Cooling System ON.
Thermostat will control temperature.
Turn OFF: Cooling system stops working.
3. Heating power management switch: Need to
have Hot switch turned ON.
Selected to HIGH position: Full Heating
power of 385 Watts at 220V is applied to
the hot tank.
Selected to LOW position: Low Heating
power of 185 Watts at 220V is applied to
the Hot tank.
4. Power Consumption Management system:
To operate need to have both, Hot and Cold switches turned ON:
Hot and Cold Together Position : Heating
and cooling work together. Power consumption is a sum of Heating and Cooling
consumption. Lowest is about 285 Watts and Highest about 485 Watts.
Hot and Cold Consecutive Position: Heating has priority. Cooling will work only
after Heating stops. Maximum Power used limited to one function only. Lowest is
100 watts for Cooling or 185 Watts for Heating only and Highest is 385 Watts for
Maximum Heater power.