Install the drive modules

Install UDO drives in MO modules

To install UDO drives into MO modules:
1. Remove the MO drives from the existing MO modules.
2. Assemble the UDO drives into drive modules. For each drive:
Note:
3. For a 4-drive jukebox, insert the two UDO drive modules into place at drive locations 1/2
1
2
3
4
Figure 11: Connection of drive cables and jumpers to the interposer board(s)
4. For a 6-drive or a 10-drive mixed-media jukebox, insert the three UDO drive modules into
5. For a 10-drive UDO-only jukebox, insert the drive modules in all locations except 5/6.
6. Secure the UDO drives to the jukebox using 2 T-20 torx screws, 1 on each side of each
3800ux/7100ux Optical Jukebox Conversion Guide
a. Insert the drive into the sheet metal drive module.
b. Connect the cables to the drive and thread them through the holes in the module.
Make sure you route the drive cables through the drive cable clamps.
c. Secure the drive to the module using two screws per side (supplied) on both sides of
the module.
d. Install and secure the cable access panel on the drive module.
and 3/4 (see
Figure
11).
8
7
Drive location 1/2
Drive location 3/4
Drive location 5/6
Drive location 7/8
place at drive locations 5/6, 3/4, and 1/2, in this order.
Locations 5/6 are to remain empty in this configuration.
drive.
Convert an MO Jukebox to UDO or Mixed-Media Technology
Drive location 9/10
5
Drive location 11/12
6
Drive cables
7
Jumper location
8
1
2
3
4
5
6