ABB GKey Quick Manual page 3

Safety lock

Advertisement

Warning!
The safety functions and the mechanics shall be tested regularly.
Warning!
In case of breakdown or damage to the product, contact the nearest ABB Jokab Safety representative. Do not
try to repair the product yourself since it may accidentally cause permanent damage to the product, impairing
the safety of the device which in turn could lead to serious injury to personnel.
Manufacturer
Address
Technical data
Supply voltage
Power consumption
Safety circuits
Auxiliary circuits (34 & 44)
Rated insulation voltage
Rated impulse withstand
Holding force
Switch holding force (F
)
Zh
Classification and coding level (EN ISO 14119)
Actuator insertion distance for assured locking
S
(RFID)
ao
S
(RFID)
ar
Operating frequency
Actuator entry minimum radius
Body material
Head material
Mechanical actuator material
Enclosure protection
Operating temperature
Mechanical life expectancy (B
Vibration
Safety / Harmonized standards
Conformity
EN ISO 13849-1
EN 62061
(used as a subsystem)
Operating assumptions
Note: If the usage of the product differs from these assumptions (different load, operating frequency, etc.) the values must be
adjusted accordingly.
Certifications
Information for use in USA/Canada
Enclosure
Maximum temperature
Conductors
Terminal torque
Intended for same polarity use
Safety circuits (11-31 & 21-41)
Push button ratings (optional)
Use one polymeric conduit connection. Not suitable for connection to rigid metal conduit. (Earth bonding terminal inside enclosure
if required – use 16-12 AWG conductors)
Descriptions and examples show how the product works and can be used. It does not mean that it fulfills the requirements for all
types of machines and processes. The buyer/user is responsible for installing and using the product according to applicable
standards and regulations. We reserve the right to make changes to the product and the documentation without prior notice.
2TLC010049M0201_C
)
10D
European Machine Directive 2006/42/EC
EN 60947-5-3, EN ISO 13849-1, EN 62061,
EN ISO 14119, UL 508
Performance level: PL e (If both channels are used in conjunction with a SIL3/PL e control
device)
Category 4, MTTF
Diagnostic coverage: DC = 99% (High)
Safety integrity level: SIL3
PFH (1/h) = 4.77E-10 (Corresponds to 4.8% of SIL3)
PFD = 4.77E-10 (Corresponds to 4.2% of SIL3)
Proof test interval T
Days per year: d
Hours per day: h
cULus, TÜV Rheinland
Type 1
40 °C
Use 16-28 AWG copper conductors (rated +90 °C)
6 lb ins. (0.7 Nm)
A300 Pilot duty 240 V 3A
(PF 0.38 or greater tested for 6,000 cycles endurance)
120 - 240 VAC, 1.5 - 1.0 A
24 - 125 VDC, 0.3 - 0.2 A
ABB AB, Jokab Safety
Varlabergsvägen 11
SE-434 39 Kungsbacka
Sweden
+24 VDC ±10 %
R+ 1.2 W (50 mA max.)
S+ 12 W (500 mA max.)
+24 VDC, 200 mA max. switching
+24 VDC, 200 mA max. output feed
500 VAC
1000 VAC
F1 max. 3000 N
2307 N
Type 4 high
5 mm
10 mm
20 mm
1 Hz max.
175 mm
Die-cast metal aluminum alloy
Stainless steel
Stainless steel
IP65
-25 °C to +40 °C
2.5 x 10
6
cycles at 100 mA load
IEC 60068-2-6, 10-55 Hz+1 Hz
Excursion: 0.35 mm, 1 octave/min
1100 a
d =
= 20 a
1
= 365 d
op
= 24 h
op