Figure 6-8 Reflow profile
° C
300
240
217
180
165
120
60
0
Table 6-2 Reflow parameters
Temperature Zone
Preheat zone
(40° C–165° C)
Soak zone
(165° C–217° C)
Reflow zone (> 217° C)
Cooling zone
Issue 09 (2017-12-15)
60s~100s
Time
-
(t1–t2): 60s–100s
(t3–t4): 45s–80s
Cooling rate: 2°C/s ≤ Slope ≤ 5° C/s
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
Mechanical Specifications
235° C<Tmax<245° C
45s~80s
Key Parameter
Heating rate: 0.5° C/s–2° C/s
-
Peak reflow temperature:
235° C–245° C