Application Guidelines
4B
This section of the manual presents the factory configuration file (niacfg.ini) and defines the
configuration parameters in the file and their options.

5.1 Factory niacfg.ini File

All SEC configuration options are specified in the niacfg.ini file that resides in a file system built
into the SEC. The file can be accessed and downloaded locally using a web browser, revised,
and then uploaded to the unit.
The niacfg.ini file defines how the Ethernet port of the SEC unit will operate. A copy of the
factory configuration file is shown in Table 5-1. The file is based on the standard .ini format.
Major sections are denoted within brackets [] and in the table are shown in bold type.
Comments begin with a #, and continue to the end of the line. The order of the options doesn't
matter, but each option has to be within its correct section. For example, BIT_RATE can't be in
the [UDP] section; it must be in the [GENERAL] section.
###################################################################
# This is the niacfg.ini configuration file.
# Comments go from # to end of line.
# The order of options does not matter, as long as the option is
# in the correct section.
###################################################################
[GENERAL]
# IP=169.254.1.10
# NETMASK=255.255.0.0 # Network mask
# GATEWAY=0.0.0.0
MODE=1
BIT_RATE=38400
###################################################################
# PEER Routing Options
###################################################################
PORT=60000
# UDP Port unit accepts messages on
BROADCAST=1
LEARN=1
# Allow unit to "learn" addresses sent by other units
TTL=300
# Time to Live for dynamic entry (in seconds)
PAIR=1
# 0=Use only Peer address for routing logic
# 1=Use Peer and station addresses for routing logic
Copyright 2019
The factory niacfg.ini file is provided on the CD which was
shipped with the SEC.

Table 5-1 - Factory Configuration File

# IP Address of unit
# Gateway
# 1=PEER Routing
# Bit rate
# Allow unit to send broadcasts
SM6800O Rev. 1, March 2019
®
Microlok II
Serial-to-Ethernet Converter (SEC)
NOTE
5-1