Huawei SUN2000-2KTL-L0 User Manual page 32

Hide thumbs Also See for SUN2000-2KTL-L0:
Table of Contents

Advertisement

SUN2000-(2KTL-5KTL)-L0
User Manual
Avoid drilling holes in the utility pipes and/or cables attached to back of the wall.
Figure 4-9 Expansion bolt composition
(1) Bolt
(4) Flat washer
To prevent dust inhalation or contact with eyes, wear safety goggles and an anti-dust
respirator when drilling holes.
Clean up any dust in and around the holes using a vacuum cleaner and measure the
distance between holes. If the holes are inaccurately positioned, drill a new set of the
holes.
Level the head of the expansion sleeve with the concrete wall after removing the bolt,
spring washer, and flat washer. Otherwise, the mounting bracket will not be securely
installed on the concrete wall.
Figure 4-10 Installing an expansion bolt
Step 3 Secure the mounting bracket.
Issue 01 (2018-08-30)
If the length or number of M8x80 expansion bolts supplied with the SUN2000 is not enough, prepare
M8 stainless steel expansion anchor bolts.
Copyright © Huawei Technologies Co., Ltd.
(2) Nut
(5) Expansion sleeve
4 System Installation
(3) Spring washer
26