Timer 3 Current Count Register (Tmrccr3); Timer 4 Current Count Register (Tmrccr4); Timer 1 Irq Clear (T1Ic); Table 3-8 Tmrccr12 Bit Mapping - GE VMIVME-7807 Series Hardware Reference Manual

Intel pentium m-based vme sbc
Table of Contents

Advertisement

Table 3-8 TMRCCR12 Bit Mapping

Field
Bits
Timer 2 Count
TMRCCR12[31..16]
Timer 1 Count
TMRCCR12[15..0]
When either field is read, the current count value is latched and returned. There 
are two modes that determine how the count is latched depending on the setting 
of the "Read Latch Select" bit in the WDT Control Status Register (CSR2). See the 
CSR2 register description for more information on these two modes.

3.3.7 Timer 3 Current Count Register (TMRCCR3)

The current count of Timer 3 may be read via the Timer 3 Current Count Register 
(TMRCCR3), located at offset 0x24 from the address in BAR2. The mapping of bits 
in this register is shown in Table 3‐9.

Table 3-9 TMRCCR3 Bit Mapping

Field
Bits
Timer 3 Count
TMRCCR3[31..0]
When this field is read, the current count value is latched and returned. There are 
two modes that determine how the count is latched depending on the setting of 
the "Read Latch Select" bit in the WDT Control Status Register (CSR2). See the 
CSR2 register description for more information on these two modes.

3.3.8 Timer 4 Current Count Register (TMRCCR4)

The current count of Timer 4 may be read via the Timer 4 Current Count Register 
(TMRCCR4), located at offset 0x28 from the address in BAR2. The mapping of bits 
in this register is shown in Table 3‐10.

Table 3-10 TMRCCR4 Bit Mapping

Field
Bits
Timer 4 Count
TMRCCR4[31..0]
When this field is read, the current count value is latched and returned. There are 
two modes that determine how the count is latched depending on the setting of 
the "Read Latch Select" bit in the WDT Control Status Register (CSR2). See the 
CSR2 register description for more information on these two modes.

3.3.9 Timer 1 IRQ Clear (T1IC)

The Timer 1 IRQ Clear (T1IC) register is used to clear an interrupt caused by 
Timer 1. Writing to this register, located at offset 0x30 from the address in BAR2, 
causes the interrupt from Timer 1 to be cleared. This can also be done by writing a 
"0" to the appropriate "Timer x Caused IRQ" field of the timer Control Status 
Register (CSR1). This register is write only and the data written is irrelevant.
Read or Write
Read Only
Read Only
Read or Write
Read Only
Read or Write
Read Only
Embedded PC/RTOS Features 37