Download Print this page

Basic Operation - Panasonic MICRO-IMAGECHECKER AX40 User Manual

Color extraction
Hide thumbs Also See for MICRO-IMAGECHECKER AX40:

Advertisement

Basic Operation

AX40
The inspection procedure is mainly devided into 5 steps. Setting items may vary depending on the
environmental condition, inspection types and checker types.
This manual mainly explains the step 4 Checker settings, basic and applied operation using the color extraction.
Regarding with the details of checkers, input/output from the external devices and the communication, refer to
the User's manual (Hardware and Operation).
1 Setting the image processing
Select the type of the image processing from "Color", "Gray" or "Differential" for the inspection
image to be set on "Memory1" and "Memory2".
Note that the default setting is "Color" for both Memory1 and Memory2.
2
Setting the product type
Up to 16 product types can be set.
3
Capturing the image
Press the A key to capture.
4
Setting the checker
Specify the checker no.
5
Setting the tool
Calculation, Statistics and Output
For more details about checkers, refer to the User's manual (Hardware and Operation).
Up to 99 (No.1 to No.99) can be set.
Adjustment Checker *
POSITION ADJUSTMENT
ROTATION ADJUSTMENT
* The specified number of adjustment checkers should be set smaller than the ones of
inspection checkers in sequence. This enables adjustment checkers to follow the
inspection checkers.
Inspection Checker **
BINARY WINDOW
GRAY WINDOW
BINARY EDGE
GRAY EDGE
FEATURE EXTRACTION
SMART MATCHING
CONTOUR MATCHING
** Note that checkers in gray color cannot be selected. Available checkers can be
determined by the initial settings of "Memory1" and "Memory2."
Numerical Calculation
Judgement
4

Advertisement

loading