Figure 19. Pushing the special nuts in place in the corners of the cabinet.
12. Lead the cable via the swivel into the cabinet. Note: the cable length in the cabinet
must be 20 cm (this includes the RJ45 connector which you have to mount to the
cable later on).
Note:
At the outside of the box, the cable must be led directly from the cabinet
into the building to avoid exposing the cable to lightning.
13.
Tighten the cable inlet on the swivel and make sure that the cable inlet is waterproof.
14. Mount the RJ45 connector to the cable using the tool for mounting an RJ45 connector
plug to a Category 5 cable. For standard colour schemes, consult Chapter 4. WIRE
COLOUR CODING FOR CATEGORY 5 CABLES.
15. Open the AP300E box by means of removing the two screws at the rear side of the
AP300E.
16. Use a small pair of tongs to open the predefined holes in the AP300 cabinet.
14
All rights reserved. Reproduction in whole or in part is prohibited without the written consent of the copyright owner
Outdoor Cabinet Isolated - Installation Manual
March 2010