MTBF (Mean Time Between Failures)
Mechanical specifications
Housing
•
•
Recommended distance to metal
Power supply
Permitted ambient conditions
Ambient temperature
•
•
Degree of protection to EN 60529
Shock-resistant to EN 60721-3-7 class 7M3
Vibration-resistant to EN 60721-3-7, class 7M3
Torsion and bending load
Design, dimensions and weight
Dimensions (Ø x H)
Weight
Type of mounting
The values for shock and vibration are maximum values and must not be applied continuously.
1)
) To prevent it loosening during operation, secure the screw with screw locking varnish.
2
SIMATIC RF200
System Manual, 07/2015, J31069-D0227-U001-A9-7618
Material
Color
During operation
During transportation and storage
2 x 10
hours
6
Epoxy resin
•
Black
•
> 25 mm
Inductive, without battery
-25 to +85 ℃
•
-40 to +100 ℃
•
IP67
•
IPx9K
•
100 g
1)
20 g
1)
Not permitted
27 x 4 mm
5 g
Glued
•
1 x M3 screw
•
2)
≤ 1 Nm
Transponder
7.18 MDS D424
6GT2600-4AC00
261