Settings In Cc-Link Ie Field Network - Mitsubishi Electric MELSEC iQ-R Series Reference Manual

Inter-module synchronization function
Hide thumbs Also See for MELSEC iQ-R Series:
Table of Contents

Advertisement

6.3

Settings in CC-Link IE Field Network

Set this to synchronize with the inter-module synchronization cycle using the CC-Link IE Field network synchronous
communication function. This setting is made in the master station.
[Module Parameter]  "Basic Settings"  "Network Configuration Settings"  "Detailed Setting"
Window
Displayed items
Item
Network Synchronous Communication
• Set the ring device assignments so the network synchronous communication target station and non-target
station are in succession. If these are not in succession, the time for the refreshing process at the inter-
module synchronization interrupt will take longer.
Refresh takes longer because a synchronous area
and an asynchronous area comes alternately.
• For local stations and slave stations other than the remote head module, parameters must be set
individually. Refer to the manual for each slave station for details.
Description
Sets whether to coordinate the inter-module
synchronization cycle with the CC-Link IE Field Network
synchronous communication function.
Setting range
• Asynchronous
• Synchronous
Refresh takes shorter because the same areas
(synchronous or asynchronous) come continuously.
6 PARAMETER SETTINGS
6.3 Settings in CC-Link IE Field Network
6
Default
Asynchronous