Siemens SIMATIC Ident Compact Operating Instructions page 12

Code reader systems
Hide thumbs Also See for SIMATIC Ident:

Advertisement

5. Select "Assign IP parameters" and enter the values for the IP address and subnet mask as shown below.
Note
IP address 192.168.100.100
● Using the IP address 192.168.100.100, the reader is configured as a DHCP server at the same time, which means
that a connected PC can obtain an IP address from the reader. By manually assigning addresses that differ from this
IP address and that are not 0.0.0.1, you configure a static IP address for the reader. PCs operated in a network are
usually configured as DHCP clients and obtain their IP addresses from a server.
● If your PC network is configured differently or you do not know how your PC is configured, check with your system
administrator.
6. Now select the MV440 or MV420 module again and then load the configuration on the reader by clicking the "Download"
menu command in the "Module" menu
10
SIMATIC MV420/SIMATIC MV440
A5E02370910-06, 04/2013