Siemens SCALANCE X-300EEC Compact Operating Instructions

Simatic net industrial ethernet switches
Hide thumbs Also See for SCALANCE X-300EEC:
Table of Contents

Advertisement

SCALANCE X-300EEC
SIMATIC NET
Industrial Ethernet switches
SCALANCE X-300EEC
Compact Operating Instructions
11/2015
A5E02630809-09
___________________
Introduction
___________________
Safety notes
___________________
Description
___________________
Assembling
___________________
Connecting
___________________
Technical data
___________________
Dimension drawings
___________________
Approvals
1
2
3
4
5
6
7
8

Advertisement

Table of Contents
loading

Summary of Contents for Siemens SCALANCE X-300EEC

  • Page 1 ___________________ SCALANCE X-300EEC Introduction ___________________ Safety notes ___________________ SIMATIC NET Description ___________________ Assembling Industrial Ethernet switches SCALANCE X-300EEC ___________________ Connecting ___________________ Technical data Compact Operating Instructions ___________________ Dimension drawings ___________________ Approvals 11/2015 A5E02630809-09...
  • Page 2 Note the following: WARNING Siemens products may only be used for the applications described in the catalog and in the relevant technical documentation. If products and components from other manufacturers are used, these must be recommended or approved by Siemens. Proper transport, storage, installation, assembly, commissioning, operation and maintenance are required to ensure that the products operate safely and without any problems.
  • Page 3: Table Of Contents

    Connecting devices with 24 VDC power supply ..............44 5.4.1.1 24 VDC - product group X-300EEC ..................44 5.4.1.2 Connecting the external 24 VDC power supply ..............44 5.4.1.3 Redundant power supply ......................45 SCALANCE X-300EEC Compact Operating Instructions, 11/2015, A5E02630809-09...
  • Page 4 Other properties ........................57 Dimension drawings ..........................59 Approvals ............................. 67 X-300EEC approvals and certificates ..................67 Conformity certificate ......................72 Overview of the approvals ..................... 72 Mechanical stability ........................ 73 Index ..............................75 SCALANCE X-300EEC Compact Operating Instructions, 11/2015, A5E02630809-09...
  • Page 5: Introduction

    Overview of the technical documentation of the IE Switches X-300 A CD is supplied with the IE Switches X-300 on which you will find a detailed description of the products in PDF format in the relevant subfolder. SCALANCE X-300EEC Compact Operating Instructions, 11/2015, A5E02630809-09...
  • Page 6 Security messages Note Siemens offers IT security mechanisms for its automation and drive product portfolio in order to support the safe operation of the plant/machine. Our products are also continuously developed further with regard to IT security. We therefore recommend that you regularly check for updates of our products and that you only use the latest versions.
  • Page 7: X-300Eec Product Group

    2 x power supply unit 100 to 240 VAC / 60 to 250 VDC 6GK5307-2FD00-4EA3 2 x power supply unit 100 to 240 VAC / 60 to 250 VDC 6GK5307-2FD00-4GA3 Printed board varnished * See naming key below SCALANCE X-300EEC Compact Operating Instructions, 11/2015, A5E02630809-09...
  • Page 8: Type Designations

    SC port 1000 Mbps single mode FO cable (up to max. 10 km). SC port 1000 Mbps single mode FO cable (up to max. 40 km). SC port 1000 Mbps single mode FO cable (up to max. 70 km). SCALANCE X-300EEC Compact Operating Instructions, 11/2015, A5E02630809-09...
  • Page 9: Compact Operating Instructions, 11/2015, A5E02630809

    26 km in length. • Port 21: Multimode • Port 22: LD (long distance, single mode) • Port 23: LD (long distance, single mode) SCALANCE X-300EEC Compact Operating Instructions, 11/2015, A5E02630809-09...
  • Page 10 Introduction 1.2 Type designations SCALANCE X-300EEC Compact Operating Instructions, 11/2015, A5E02630809-09...
  • Page 11: Safety Notes

    There is an additional requirement if devices are operated with a redundant power supply: If the equipment is connected to a redundant power supply (two separate power supplies), both must meet these requirements. WARNING For use in an environment with pollution level 2 SCALANCE X-300EEC Compact Operating Instructions, 11/2015, A5E02630809-09...
  • Page 12 When used in hazardous environments corresponding to Class I, Division 2 or Class I, Zone 2, the device must be installed in a cabinet or a suitable enclosure. WARNING Opening the device DO NOT OPEN WHEN ENERGIZED. SCALANCE X-300EEC Compact Operating Instructions, 11/2015, A5E02630809-09...
  • Page 13: Important Notes On Using The Device In Hazardous Areas

    DO NOT DISCONNECT WHILE CIRCUIT IS LIVE UNLESS AREA IS KNOWN TO BE NON-HAZARDOUS. WARNING Restricted area of application This equipment is suitable for use in Class I, Division 2, Groups A, B, C and D or non- hazardous locations only. SCALANCE X-300EEC Compact Operating Instructions, 11/2015, A5E02630809-09...
  • Page 14 ● Installation in a suitable cabinet. ● Installation in a suitable enclosure. ● Installation in a suitably equipped, enclosed control room. SCALANCE X-300EEC Compact Operating Instructions, 11/2015, A5E02630809-09...
  • Page 15: Description

    • Injury to persons • Loss of the approvals • Violation of the EMC regulations Use only undamaged parts. 1. Make sure that the package is complete. 2. Check all the parts for transport damage. SCALANCE X-300EEC Compact Operating Instructions, 11/2015, A5E02630809-09...
  • Page 16: X-300Eec Product Components

    ● 1 x 3-pin 1 x 3-pin ● to 250 VDC 2 x power supply unit 100 to 240 VAC / 60 ● 2 x 3-pin 2 x 3-pin ● to 250 VDC SCALANCE X-300EEC Compact Operating Instructions, 11/2015, A5E02630809-09...
  • Page 17: Characteristics Of The X-300Eec Product Group

    3.2 Characteristics of the X-300EEC product group Characteristics of the X-300EEC product group Variants The SCALANCE X-300EEC is a 19"/2 device with 9 ports for the connection of end devices or other network segments. There are 2 device types with the following ports: ● SCALANCE X302-7EEC –...
  • Page 18 In a device with a varnished printed circuit board, you may only use a C-PLUG with a varnished board. To remove the C-PLUG, open the slider and close it again after inserting the C-PLUG. SCALANCE X-300EEC Compact Operating Instructions, 11/2015, A5E02630809-09...
  • Page 19 To increase mechanical stability, secure the IE FC RJ-45 PLUGs to this securing bracket with a cable binder. LEDs of the X-300EEC You will find the meaning of the individual LEDs in the Operating Instructions (BA) of the IE Switch SCALANCE X-300. SCALANCE X-300EEC Compact Operating Instructions, 11/2015, A5E02630809-09...
  • Page 20: Ports Of The X302-7Eec

    The SCALANCE X302-7EEC has the following ports: ● 2 electrical gigabit ports (P8 to P9) ● 7 optical Fast Ethernet ports (P1 to P7) Figure 3-3 SCALANCE X302-7EEC Port number Connection type Optical: Fast Ethernet Electrical: Gigabit Ethernet SCALANCE X-300EEC Compact Operating Instructions, 11/2015, A5E02630809-09...
  • Page 21: Ports Of The X307-2Eec

    – 5 Fast Ethernet ports (P3 to P7) – 2 gigabit ports (P8, P9) ● 2 optical Fast Ethernet ports (P1, P2) Figure 3-4 SCALANCE X307-2EEC Port number Connection type Optical: Fast Ether- Electrical: Fast Ethernet Electrical: Gigabit Ethernet SCALANCE X-300EEC Compact Operating Instructions, 11/2015, A5E02630809-09...
  • Page 22: Signaling Contact

    A. 2. Hold down the SELECT/SET button for 12 seconds. If you release the button before the 12 seconds have elapsed, the reset is canceled. SCALANCE X-300EEC Compact Operating Instructions, 11/2015, A5E02630809-09...
  • Page 23 3. The result of the action depends on the initial situation: – If the redundancy manager and media redundancy were disabled, media redundancy is also enabled after enabling the redundancy manager. – If you disable the redundancy manager, media redundancy remains enabled. SCALANCE X-300EEC Compact Operating Instructions, 11/2015, A5E02630809-09...
  • Page 24: Led Display

    Bad firmware image. During normal operation, the "F" LED provides the following information: LED color LED status Meaning during operation No operating problems. The device has detected an error. The signaling contact opens. SCALANCE X-300EEC Compact Operating Instructions, 11/2015, A5E02630809-09...
  • Page 25 For devices with power supply unit 24 to 48 VDC: Limit voltage = 17 VDC • For devices with a multiple range power supply unit 100 to 240 VAC / 60 to 250 VDC: • Limit voltage = 46.5 VDC or 80 VAC SCALANCE X-300EEC Compact Operating Instructions, 11/2015, A5E02630809-09...
  • Page 26 4 times per sec- Port exists and is in the "monitor port" status. In this sta- tus, the data traffic of another port is mirrored to this port. SCALANCE X-300EEC Compact Operating Instructions, 11/2015, A5E02630809-09...
  • Page 27 The port is monitored, in other words, if no connection was established at the port (for example no cable insert- ed), this triggers the signaling contact and an error state results. SCALANCE X-300EEC Compact Operating Instructions, 11/2015, A5E02630809-09...
  • Page 28: C-Plug

    Inserting a C-PLUG that does not contain the configuration of a compatible device type, accidentally removing the C-PLUG or general malfunctions of the C-PLUG are signaled by the diagnostics mechanisms of the device (LEDs, Web-based management, SNMP, CLI and PROFINET diagnostics). SCALANCE X-300EEC Compact Operating Instructions, 11/2015, A5E02630809-09...
  • Page 29: Removing And Inserting The C-Plug (Compact Housing)

    3. The housing of the C-PLUG has a protruding ridge on the long side (position B). The slot has a groove at this position. Insert the C-PLUG correctly oriented into the slot. 4. Close the housing again with the sealing screw. SCALANCE X-300EEC Compact Operating Instructions, 11/2015, A5E02630809-09...
  • Page 30 Description 3.5 C-PLUG SCALANCE X-300EEC Compact Operating Instructions, 11/2015, A5E02630809-09...
  • Page 31: Assembling

    When installing and operating the device, keep to the installation instructions and safety- related notices as described here and in the manual SIMATIC NET - Twisted Pair and Fiber Optic Networks. Unless stated otherwise, the installation options listed below apply to all device variants. SCALANCE X-300EEC Compact Operating Instructions, 11/2015, A5E02630809-09...
  • Page 32: Overview Of The Methods Of Installation

    ● Wall mounting ● 19" rack mounting Note Standard rail and wall mounting of the IE Switch X-300EEC With the X-300EEC, note the special features in the relevant subsection on standard rail or wall mounting. SCALANCE X-300EEC Compact Operating Instructions, 11/2015, A5E02630809-09...
  • Page 33: Installation On A Din Rail

    On the X-300EEC with power supply 100 to 240 V AC, you must always connect protective ground via the bolts on the bottom of the device housing. See also Connecting the switch (Page 40) SCALANCE X-300EEC Compact Operating Instructions, 11/2015, A5E02630809-09...
  • Page 34: Installation On A Standard Rail

    To remove the switch from the SIMATIC S7-300 standard rail, follow these steps: 1. Disconnect all connected cables. 2. Loosen the screws on the underside of the standard rail and lift the switch away from the rail. SCALANCE X-300EEC Compact Operating Instructions, 11/2015, A5E02630809-09...
  • Page 35: Wall Mounting

    Note To mount the IE Switch X-300EEC on a wall, you require an additional securing bracket. You will find the dimensions for a suitable securing bracket in section Dimension drawings (Page 59). SCALANCE X-300EEC Compact Operating Instructions, 11/2015, A5E02630809-09...
  • Page 36: 19" Rack Mounting

    Figure at top: Rear of the switches Figure at bottom: View from below Table 4- 2 Legend for rack mounting of two IE-Switches X-300EEC fastened together Name Plate for side Spring washer Hexagonal nut SCALANCE X-300EEC Compact Operating Instructions, 11/2015, A5E02630809-09...
  • Page 37 Assembling 4.6 19" rack mounting Name Side section (the side panel should be under slight tension) IE Switch X-300EEC SCALANCE X-300EEC Compact Operating Instructions, 11/2015, A5E02630809-09...
  • Page 38 Assembling 4.6 19" rack mounting SCALANCE X-300EEC Compact Operating Instructions, 11/2015, A5E02630809-09...
  • Page 39: Connecting

    "Standby connection" must be "enabled" and the "Standby connection name" must match the name of the partner device. You will also need to configure the port with "Enable Standby Port Monitoring" (see "Configuration Manual SCALANCE X-300 / X-400", section "X-300/X-400 Standby Mask"). SCALANCE X-300EEC Compact Operating Instructions, 11/2015, A5E02630809-09...
  • Page 40: Connecting The Switch

    With devices with a supply voltage of 100 to 240 VAC / 60 to 250 VDC, you should also connect the protective earth to the grounding bolt. On the SCALANCE X-300EEC, the grounding bolt is on the bottom of the device. On the SCALANCE XR-300M EEC, the grounding bolt is on the rear of the housing between the power connectors.
  • Page 41 To wire up the protective ground, use a copper cable of category 14-8 AWG or cable with a cross-section of 1.5 to 6 mm². Grounding bolts on the underside of the housing of the X-300EEC or on the rear of the XR- 300M-EEC SCALANCE X-300EEC Compact Operating Instructions, 11/2015, A5E02630809-09...
  • Page 42: Signaling Contact

    0.75 to 2.5 mm². NOTICE Laying the connecting cables of the signaling contact with the X-300EEC To improve the EMC properties (surge protection), the two connecting cables of the signaling contact should be laid together. SCALANCE X-300EEC Compact Operating Instructions, 11/2015, A5E02630809-09...
  • Page 43: Signaling Contact 100 To 240 Vac / 60 To 250 Vdc

    Make sure that the connector cannot be released accidentally by pulling on the connecting cable. Lay the cables in cable ducts or cable channels and secure the cables, where necessary, with cable ties. SCALANCE X-300EEC Compact Operating Instructions, 11/2015, A5E02630809-09...
  • Page 44: Power Supply

    • The signaling contact can be subjected to a maximum load of 100 mA (safety extra-low voltage (SELV) 24 V DC). • Never operate the device with AC voltage or DC voltage higher than 58 V DC. SCALANCE X-300EEC Compact Operating Instructions, 11/2015, A5E02630809-09...
  • Page 45: Redundant Power Supply

    If you connect an X-300EEC with redundant power supply units 24...48 V DC to two power supplies, you will need to connect the power supply to terminal "L1" on both power supply units. Only "L1" is monitored on each connector. SCALANCE X-300EEC Compact Operating Instructions, 11/2015, A5E02630809-09...
  • Page 46: Connecting A Redundant Power Supply To The X-300Eec

    ● If the power supply fails at pins L1/M1, this is indicated by LED L1. ● If the power supply fails at pins L2/M2, this is indicated by LED L2. SCALANCE X-300EEC Compact Operating Instructions, 11/2015, A5E02630809-09...
  • Page 47: Connecting Devices With 100 To 240 Vac Power Supply

    2 x 100 to 240 VAC / 60 to 250 VDC ● X307-2EEC 1 x 100 to 240 VAC / 60 to 250 VDC ● 2 x 100 to 240 VAC / 60 to 250 VDC ● SCALANCE X-300EEC Compact Operating Instructions, 11/2015, A5E02630809-09...
  • Page 48: Notes On The Power Supply 100 To 240 Vac

    Make sure that the connector cannot be released accidentally by pulling on the connecting cable. Lay the cables in cable ducts or cable channels and secure the cables, where necessary, with cable ties. SCALANCE X-300EEC Compact Operating Instructions, 11/2015, A5E02630809-09...
  • Page 49: Connecting The 100 To 240 Vac Power Supply

    With devices with a supply voltage of 100 to 240 VAC / 60 to 250 VDC, you should also connect the protective earth to the grounding bolt. On the SCALANCE X-300EEC, the grounding bolt is on the bottom of the device. On the SCALANCE XR-300M EEC, the grounding bolt is on the rear of the housing between the power connectors.
  • Page 50 DC voltage is connected at the following terminals: ● Plus to "L" ● M to "N" Secure the firm seat of connectors and the terminal block by tightening the screws (does not apply to X-300EEC). SCALANCE X-300EEC Compact Operating Instructions, 11/2015, A5E02630809-09...
  • Page 51: Technical Data

    2 x power supply units 2120 g IP30 Without clip: • 100 to 240 VAC / 60 to 250 60 × 125 × 123 mm With clip: • 216 × 203 × 99 mm SCALANCE X-300EEC Compact Operating Instructions, 11/2015, A5E02630809-09...
  • Page 52 -40 °C to +70 °C < 95 % (no conden- Max. 65 ℃ as of 2000 m sation) Max. 60 ℃ as of 3000 m The IE Switch was type tested for 16 h at +85 °C. SCALANCE X-300EEC Compact Operating Instructions, 11/2015, A5E02630809-09...
  • Page 53 Velocity: <10 mm/s • (IEEE1613 Class V.S.2) Frequency: 1 to 150 Hz • Shock Acceleration: 15 g • (IEC 60068-2-27) Duration of the pulse: 11 ms • Number of shocks per direction: 3 • SCALANCE X-300EEC Compact Operating Instructions, 11/2015, A5E02630809-09...
  • Page 54: Connectors And Electrical Data

    0.5 to 0.3 A 12 W 100 to 240 VAC / 60 to 250 0.3 to 0.2 A (AC) 12 to 13 W (AC) 0.3 to 0.1 A (DC) 12 to 13 W (DC) SCALANCE X-300EEC Compact Operating Instructions, 11/2015, A5E02630809-09...
  • Page 55 Electrical data: Transmitter output (optical) and receiver input Transmitter output (optical) Receiver input min. [dBm] max. [dBm] Sensitivity min. [dBm] Input power max. [dBm] Values for glass fiber: 62.5 to 125 μm multimode SCALANCE X-300EEC Compact Operating Instructions, 11/2015, A5E02630809-09...
  • Page 56: Cable Lengths

    62.5/125 μm 0 to 5 km ≤1 dB/km at 1310 nm; 1200 MHz×km; maximum insertion loss 50/125 μm, 0.5 dB; 9 dB max. permitted FO cable attenuation at 3 dB link power margin SCALANCE X-300EEC Compact Operating Instructions, 11/2015, A5E02630809-09...
  • Page 57: Other Properties

    These values apply at 40 °C. Note The IE Switches X-300 support "full wire speed switching" complying with IEEE 802.3 on all ports. The number of packets therefore depends on the packet length. SCALANCE X-300EEC Compact Operating Instructions, 11/2015, A5E02630809-09...
  • Page 58 • at 64 bytes frame length: Delay of approx. 10 microseconds (at 100 Mbps) • at 1500 bytes frame length: Delay of approx. 130 microseconds (at 100 Mbps) This means, the more IE Switches X-300 a frame runs through, the higher the frame delay. SCALANCE X-300EEC Compact Operating Instructions, 11/2015, A5E02630809-09...
  • Page 59: Dimension Drawings

    Dimension drawings All dimensions in the drawings are in millimeters Figure 7-1 Dimension drawing IE Switch X302-7EEC - view SCALANCE X-300EEC Compact Operating Instructions, 11/2015, A5E02630809-09...
  • Page 60 Dimension drawings Figure 7-2 Dimension drawing IE Switch X302-7EEC - side view Figure 7-3 Dimension drawing IE Switch X302-7EEC - from above SCALANCE X-300EEC Compact Operating Instructions, 11/2015, A5E02630809-09...
  • Page 61 You will find other accessories, such as screws in the tables. If you have questions, contact our Customer Support. You will also find dimension drawings on the Internet on the pages of Siemens Industry Automation Customer Support under the following entry ID: 33118441 (http://support.automation.siemens.com/WW/view/en/33118441)
  • Page 62 Dimension drawings Mounting support for EEC wall mounting Figure 7-4 X-300EEC wall mounting (dimensions in mm) SCALANCE X-300EEC Compact Operating Instructions, 11/2015, A5E02630809-09...
  • Page 63 Rack mounting of two X-300EECs fastened together (view from below) Table 7- 1 Legend for rack mounting of two X-300EECs fastened together Number needed Name Plate for side Spring washer SN60727-4-NrSt Hexagonal nut ISO 4032-M4-8 Mid part of mounting support SCALANCE X-300EEC Compact Operating Instructions, 11/2015, A5E02630809-09...
  • Page 64 Dimension drawings Figure 7-6 Side part of mounting support for X-300EEC (dimensions in mm) Material: Plate 2.0 DIN EN10152 DC01+ZE25/25 SCALANCE X-300EEC Compact Operating Instructions, 11/2015, A5E02630809-09...
  • Page 65 Dimension drawings Figure 7-7 Middle part of mounting support for X-300EEC (dimensions in mm) Material: Plate 2.0 DIN EN10152 DC01+ZE25/25 See also 19" rack mounting (Page 36) SCALANCE X-300EEC Compact Operating Instructions, 11/2015, A5E02630809-09...
  • Page 66 Dimension drawings SCALANCE X-300EEC Compact Operating Instructions, 11/2015, A5E02630809-09...
  • Page 67: Approvals

    The term "the product" as used below includes all device variants of the SCALANCE X-300EEC unless specific variants are expressly named for an approval. EC directives SIMATIC NET products meet the requirements and aims of the following EC directives.
  • Page 68 (http://support.automation.siemens.com/WW/view/en/27069465)", in "Further documentation". – "EMC Installation Guidelines" configuration manual ID = 60612658 (http://support.automation.siemens.com/WW/view/en/60612658) ● Working on the device To protect the device from electrostatic discharge, personnel must first discharge any electrostatic charge from their body before touching the device.
  • Page 69 Area". You will find this document • on the data medium that ships with some devices. • on the Internet pages of Siemens Industry Online Support (http://support.automation.siemens.com/WW/view/en). Enter the document identification number C234 as the search term. SIMATIC NET products meet the requirements of the EC directive:94/9/EC "Equipment and Protective Devices for Use in Potentially Explosive Atmospheres".
  • Page 70 Non Incendive / Class I / Zone 2 / Group IIC / T4 Note Only variants with 24 VDC power supply meet the requirements of this approval. C-Tick The product meets the requirements of the AS/NZS 2064 standard (Class A). SCALANCE X-300EEC Compact Operating Instructions, 11/2015, A5E02630809-09...
  • Page 71 Cl. 1, Div. 2, GP A, B, C, D T4 Cl. 1, Zone 2, GP IIC T4 Report no. E240480 Note Only variants with 24 VDC power supply meet the requirements of this approval. SCALANCE X-300EEC Compact Operating Instructions, 11/2015, A5E02630809-09...
  • Page 72: Conformity Certificate

    24 to 48 ● ● ● ● ● ● 7EEC X302- 100...240 ● ● ● 2EEC VAC / 60...250 For temperature information "T.." or the maximum ambient temperature "Ta:..", refer to the type plate. SCALANCE X-300EEC Compact Operating Instructions, 11/2015, A5E02630809-09...
  • Page 73: Mechanical Stability

    Approvals 8.4 Mechanical stability Mechanical stability All variants of the IE Switch SCALANCE X-300EEC meet the following requirements for mechanical stability: ● IEC 60068-2-6 (vibration) 5 – 9 Hz: 3.5 mm 9 – 150 Hz: 1 g 1 octave/min, 20 sweeps ●...
  • Page 74 Approvals 8.4 Mechanical stability SCALANCE X-300EEC Compact Operating Instructions, 11/2015, A5E02630809-09...
  • Page 75: Index

    PH - Configuration Manual, 6 Possible attachments SCALANCE X302-7, 17 Power supply Redundancy, 49 Redundancy Power supply, 45, 49 Signaling contact redundant, 19 SIMATIC NET glossary, 6 System manual, 68 X-300EEC power supply Redundancy, 45 SCALANCE X-300EEC Compact Operating Instructions, 11/2015, A5E02630809-09...
  • Page 76 Index SCALANCE X-300EEC Compact Operating Instructions, 11/2015, A5E02630809-09...

Table of Contents