Profibus Pnu; Real-Time Monitor - Mitsubishi Electric FR-A5NPA Instruction Manual

Profibus/dp communication option
Table of Contents

Advertisement

PARAMETER DEFINITIONS - A500/F500 SERIES

7.2 Profibus PNU

7.2.1 Real-time monitor

The following items can be monitored from the master.
PNU
P1.1
Output frequency
P1.2
Output current
P1.3
Output voltage
P1.5
Frequency setting
P1.6
Running speed
P1.7
Motor torque
P1.8
Converter output voltage
P1.9
Regenerative brake duty
P1.10
Electronic overcurrent protection load factor
P1.11
Output current peak value
P1.12
Converter output voltage peak value
P1.13
Input power
P1.14
Output power
P1.15
Input terminal status (refer to page 49 (1))
P1.16
Output terminal status (refer to page 49 (2))
P1.17
Load meter
P1.18
Motor excitation current
P1.19
Position pulse*
P1.20
Cumulative energization time
P1.22
Orientation status*
P1.23
Actual operation time
P1.24
Motor load factor
P1.25
Cumulative power
* Can be monitored only when the FR-A5AP is fitted.
Item
48
Data
Unit
Type
0.01Hz
AUs16
0.01A
AUs16
0.1V
AUs16
0.01Hz
AUs16
1r/min
AUs16
0.1%
AUs16
0.1V
AUs16
0.1%
AUs16
0.1%
AUs16
0.01A
AUs16
0.1V
AUs16
0.01kW
AUs16
0.01kW
AUs16
-
AUs16
-
AUs16
0.1%
AUs16
0.01A
AUs16
-
AUs16
1h
AUs16
-
AUs16
1h
AUs16
0.1%
AUs16
1kWh
AUs16