Controlling the safety functions
5.4 Activating "SBC" via the Safe Brake Adapter
Interfaces
Figure 5-8
Table 5- 25
Terminal block X11, interface to the Control Interface Module
Connection
Signal
X11.1
BR+
X11.2
BR-
X11.3
FB+
X11.4
FB-
X11.5
P24
X11.6
M
Max. connectable cross-section 2.5 mm
92
Safe Brake Adapter interface overview 230 VAC
Description
Control channel 1
Control channel 2
Relay feedback signal
Ground of the relay feedback signal
P24 of the auxiliary voltage to supply
the feedback signal
Ground of the auxiliary voltage
2
Technical data
Connection to the Control Interface Module, X46:1
Connection to the Control Interface Module, X46:2
Connection to the Control Interface Module, X46:3
Connection to the Control Interface Module, X46:4
Connection to the Control Interface Module, X42:2
Connection to the Control Interface Module, X42:3
Function Manual, 07/2016, A5E03264275A
Safety Integrated