[1]
3.4.3.5 Removing the Lower-left Cover of the Optional
Tray
1) Remove the two RS tightening screws (M3 x 8) [1], and then remove the
lower-left cover of the optional tray [2].
[2]
3.4.3.6 Removing the Top Cover of the Optional Tray
1) Remove the two P tightening screws (M4 x 12) [1], and then remove the
RS tightening screw (M3 x 8) [2]. Disconnect the connector [3], and then
detach the top cover [4] of the optional tray.
[4]
3.4.3.7 Removing the Electrostatic Discharge Needle
1) Remove the binding screw (M3 x 4) [1], and then remove the electrostatic
discharge needle 1 [2] by sliding it in the direction of the arrow.
[2]
F-3-24
[1]
F-3-25
[1]
[2]
[3]
F-3-26
3.4.4 Tray Clock Sensor
3.4.4.1 Removing the Stack Tray Assmbly Harness
1) Remove the screw [1], and then remove the sensor mounting plate [2].
2) Remove the harness from the two wire saddles [3], and then remove the
reusable band [4].
0010-6818
3.4.4.2 Removing the Tray Guide Top Cover
1) Remove the two RS tightening screws (M3 x 8) [1], and then detach the
rear cover [2] of the tray.
0010-6819
[1]
F-3-29
3.4.4.3 Removing the Stack Tray Assmbly
0010-6820
1) Holding the stack tray [1], remove it in the direction of the arrow.
[1]
[2]
F-3-27
[4]
[3]
[2]
F-3-28
[2]
Chapter 3
0010-6801
[1]
0010-6802
0010-6803
3-5