Motorola R-2400 Operator's Manual page 23

Communications service monitor
Hide thumbs Also See for R-2400:
Table of Contents

Advertisement

iil*SN
j;r*::'i:i::i:;::i:*i'|rr*i::r:::;i
ji:ii:ri::..
3.6.0
OSCIIOSCOPE/SPECTRUM
ANALYZER/MODUTATION
SCOPE SECTION
3.6.6
VERT
A
four position rotary
switch
controls the vertical
dis-
play. Oscilloscope operation
uses
values
marked
to
the
right of
the switch
indicating volts per division.
Values
marked
to the left of the switch
are
used
when modula-
tion
is displayed
on the oscilloscope. The right
bezel
of
the
oscilloscope has a
numerical
scale
corresponding
to
values
of
.25
kHz, 2.5 kHz
and 25 kHz per division.
This allows deviation
measurements
to
be made
even
when
the
service
monitor LCD display
is
not
selected
to
"DEV/VIAM"
and
gives
the technician the ability to
detect
non-symmetric modulation. This switch
is
dis-
abled when
the
R-2400
spectrum
analyzer is being
used.
3.6.7
VERT VERNIER
The vertical vernier potentiometer controls the vertical
inputs
to
the
oscilloscope.
The calibrated position
is
fully
clockwise.
NOTE: The vertical vernier potentiometer is also
func-
tional
when
the R-2400 spectrum
analyzer
mode
is
being
used.
It
is
important to
have
this
control in the "Cal"
posi-
tion to
ensure
true l0dB/div vertical
accuracy.
FIGURE
3.s-CLOSEUP
OF SCOPE TRACE
3.6.8
POSITION
The stacked concentric potentiometers control the
ver-
tical and horizontal positions
of
the
scope trace.
For
R-2400 spectrum analyzer operation, these
con-
trols are
also used
to
center
the
observed
spectrum.
when
entering
the
spectrum analyzer mode, use
the
"Vert Position" control
(innermost control)
to
set
the
base
of
the noise
floor at
the bottom graticule.
The
Horiz Position control is
adjusted
by first
programm-
ing for an RF
frequency
of
000.0000
Mhz
(dc
reference),
then with the
dispersion
control set for
lMhz/div,
use
the Horiz Position control
(outermost
potentiometer)
to
center
the
observed
spectrum display
horizontally around the center (sth) vertical graticule.
'
*i,$,i,t..i.rf,*i'.
,l:::,,,]t't,t,:,lll
-'.,,'
$r1ig\
I"i'i
til
i-.+\,
i
$'
$;
j
J.
5is..riis;$;r+'l.
i
j,$'$
FIGURE 3-4-CLOSEUP OF SCOPE CONTROLS
3.6.1 INTENSITY
The intensity control varies the brightness of the
scope
trace.
3.6.2
FOCUS
The focus
control
varies the
sharpness
of
the
scope
trace.
3.6.3
HORIZ
This
seven
position rotary switch
selects
the
horizontal
sweep
rate
or
the external hori zontal
sweep
input
when
the oscilloscope
function is being
used.
On the R-2400,
this
same
control is
used
to
select
the
dispersions
of l,
.1, and
.01
MHz/div
when the spectrum analyzer func-
tion
is
selected
with the function switch. The
sweep
rate
is
automatically fixed when
in
the spectrum
analyzer
mode.
3.6.4
HORIZ
VERNIER
This potentiometer controls the horizontal
sweep rate
when
the
oscilloscope functions
is
being used.
The
calibrated
position is the
fully
clockwise
position. This
control is disabled when the
R-2400
spectrum analyzer
function is being
used.
3.6.5
SOURCE
The source
control
is
a
three position rotary
switch
which
selects
the source
for
the
scope
vertical input.
"MOD"
(modulation)
will
display tho outgoing RF modulation
signal
or the
recovered modulation signal. The
"EXT
AC"
(external
AC)
position
selects
AC coupled external
input frorn the BNC connector. The
"EXTDC"
(exter-
nal
DC) position
selects
the DC coupled external input
from the
same
BNC
connector.
3-8

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

R-2200

Table of Contents