Handling instructions
Wiring to motor
• Wiring work should be performed by qualified electrician.
• Turn off power and remain off until the wiring is completed.
Grounding (earth ground)
• Positively connect the equipment to the ground.
• Use only the grounding screw provided on the product. Tighten the screw with a toque of 1.2 N·m to 1.5 N·m
(recommended).
• For grounding a motor with seal connector, connect the connector internal ground terminal to the earth.
• Use screw, spring washer and flat washer made of stainless steel or copper alloy in the grounding circuit.
• Use round terminal as grounding terminal. Do not use U-shaped terminal.
Earth terminal screw
<Precautions>
Round ground terminal and grounding leadwire, and grounding screw, spring washer and flat washer on the ground
return circuit should be prepared by the customer. Earth grounding leadwire should be of size ø1.6 mm (2 mm
more.
Leadwire
Don't forcibly bend, pull or pinch motor leadwires.
Connection
• Connections or joints of motor leadwires, power cable and capacitor should be made using soldering, connector or
crimping terminal, whichever suitable, and should be covered with appropriate insulating material.
• Clamp the motor leadwires on the equipment at stable area so that the leadwires are kept stress free.
Panasonic Corporation Electromechanical Control Business Division
industrial.panasonic.com/ac/e/
– A-40 –
© Panasonic Corporation 2018 
AQCTB02E 201806-E
Connecting to the terminal block with seal connector
Tightening torque of the screw used for the terminal box is shown in the table below.
Place of use
Screw for cap
Terminal block cover mounting screw
Clamping screw
Earth terminal screw
The applicable wires to the terminal block are as follows.
Applicable cabtire cable outer diameter
Stranded wire
Core wire
diameter
Single wire
Earth wire
stripping length
• Earth grounding leadwire should be of size ø1.6 mm (2 mm
• Don't squeeze the insulation of the lead wire with the clamp.
• The lead wire should not have fraying conductors.
) or
2
• Don't solder conductor of the lead wire.
• Clamp the motor leadwires on the equipment at stable area so that the leadwires are kept stress free.
Terminal block cover mounting screw
Terminal block
Panasonic Corporation Electromechanical Control Business Division
industrial.panasonic.com/ac/e/
AWG-JIS Comparison table
Cross sectional
Tightening torque (N·m)
AWG
3.75 to 4.0
AWG24
0.78 to 0.98
AWG22
0.39 to 0.49
AWG20
1.2 to 1.5
AWG18
AWG16
AWG14
ø8 mm to ø12 mm
AWG14 to AWG20
stripping length
AWG14 to AWG20
7 mm to 7.5 mm
AWG14 or more
7 mm to 7.5 mm
) or more.
2
Clamping screw
Leadwires (Loosely bundle leadwires.)
Screw for cap
Motor
Earth terminal screw (M4)*
* For grounding a motor with seal connector,
connect the connector internal ground terminal to the earth.
Terminal block
– A-41 –
© Panasonic Corporation 2018 
JIS
area (mm
)
2
0.205
0.2 sq
0.326
0.3 sq
0.518
0.5 sq
0.823
0.75 sq
1.31
1.25 sq
2.08
2 sq
AQCTB02E 201806-E