Electrical Characteristics
AC Input
(primary source only)
DC Input
(primary or secondary source)
Power Consumption
(AC and DC)
BPL signal
PSD (Power Spectral Density)
Ethernet
Serial
Proprietary – See Copyright Page
100 – 240 Vac, 50/60 Hz
Suitable for TT, TN & IT networks
Overvoltage category II (2500 V)
Pollution Degree 2
Class II (functional ground only)
Internal Fuse: T 2.5 A, 250 Vac
24 - 48 Vdc
Internal Fuse: PPTC 1.35 A, 60 Vdc
Typ. 6 W, Peak 12 W
SELV input/output
-30 dBm / Hz (Long Range mode)
-37 dBm / Hz (10 MHz mode)
-40 dBm / Hz (20 MHz mode)
-42 dBm / Hz (30 MHz mode)
SELV input/output
SELV input/output