Siemens SITRANS LG270 Operating Instructions Manual page 12

Guided wave radar 4...20 ma/hart - our-wire rod and cable probe -196...+280 c; -196...+450 c
Table of Contents

Advertisement

Flanges
Electronics module
Rod components
Centering
12
It is suitable for measured value indication and adjustment of sensors
and is connected to the sensor with a four-wire standard cable up to
50 m (164 ft) long.
You can find additional information in the operating instructions
manual "LG Remote Interface".
Screwed flanges are available in different versions according to the
following standards: DIN 2501, EN 1092-1, ASME B 16.5, JIS B 2210-
1984, GOST 12821-80.
You can find additional information in the supplementary instructions
manual "Flanges according to DIN-EN-ASME-JIS" (Document-ID
47574).
The electronics module SITRANS series LG is a replacement part for
TDR sensors of SITRANS series LG. There is a different version avail-
able for each type of signal output.
You can find further information in the operating instructions manual
"Electronics module SITRANS series LG".
If you are using an instrument with rod version, you can extend the
rod probe individually with curved segments and rod and cable exten-
sions of different lengths.
All extensions used must not exceed a total length of 6 m (19.7 ft).
The extensions are available in the following lengths:
Rod: ø 16 mm (0.63 in)
Basic segments: 20 ... 5900 mm (0.79 ... 232 in)
Rod/cable segments: 20 ... 5900 mm (0.79 ... 232 in)
Curved segments: 100 x 100 mm (3.94 ... 3.94 in)
You can find further information in the operating instructions manual
"Rod and cable components SITRANS series LG".
If you mount the SITRANS LG270 in a bypass tube or standpipe, you
have to avoid contact to the bypass tube by using a spacer at the
probe end.
You can find additional information in the operating instructions
manual "Centering".
SITRANS LG270 - Operating Instructions
PBD-51041064

Advertisement

Table of Contents
loading

Table of Contents