Input voltage range
(with built in Class A Filter)
Order No.
6SE6440-
Frame Size
Output Rating(CT)
Output Power
CT-Input Current 1)
CT-Output Current
VT-Input Current 1)
VT-Output Current
Fuse
Recommended
For UL specified
Input Cable, min.
Input Cable, max.
Output Cable, min.
Output Cable, max.
Weight
Tightening torques for
power terminals
Order No.
Frame Size
Output Rating(CT)
Output Power
CT-Input Current 1)
CT-Output Current
VT-Input Current 1)
VT-Output Current
Fuse
Recommended
For UL specified
Input Cable, min.
Input Cable, max.
Output Cable, min.
Output Cable, max.
Weight
Tightening torques for
power terminals
1) Secondary conditions:
*
UL listed fuses such as Class NON from Bussmann are required for use in America
MICROMASTER 440
Operating Instructions (Compact)
3 AC 380 V – 480 V. ± 10 %
2AD22-
2AD23-
2BA1
0BA1
B
2,2
3,0
[kW]
3,0
4,0
[hp]
4,5
5,9
[kVA]
7,5
10,0
[A]
5,9
7,7
[A]
[A]
[A]
16
16
[A]
3805
3805
3NA
*
3NE
2
1,5
1,5
[mm
]
16
16
[AWG]
2
6,0
6,0
[mm
]
10
10
[AWG]
2
1,0
1,0
[mm
]
18
18
[AWG]
2
6,0
6,0
[mm
]
10
10
[AWG]
3,4
3,4
[kg]
7,5
7,5
[lbs]
1,1
[Nm]
[lbf.in]
(10)
6SE6440-
2AD31-
2AD32-
8DA1
2DA1
D
18,5
22,0
[kW]
25,0
30,0
[hp]
29,0
34,3
[kVA]
37,0
43,0
[A]
38,0
45,0
[A]
43,0
59,0
[A]
45,0
62,0
[A]
63
80
[A]
3822
3824
3NA
1818-0
1820-0
3NE
2
10,0
16,0
[mm
]
8
[AWG]
2
35,0
35,0
[mm
]
2
[AWG]
2
10,0
16,0
[mm
]
8
[AWG]
2
35,0
35,0
[mm
]
2
[AWG]
17,0
17,0
[kg]
37,0
37,0
[lbs]
[Nm]
[lbf.in]
Input current at the rated operating point - applies for the short-circuit voltage of the line
supply V
= 2 % referred to the rated drive converter power and a rated line supply voltage
k
of 400 V without line commutating reactor.
2AD24-
2AD25-
0BA1
5CA1
4,0
5,5
5,0
7,5
7,8
10,1
12,8
15,6
10,2
13,2
17,3
20,2
20
20
3807
3807
*
*
*
2,5
2,5
14
14
6,0
10,0
10
8
1,0
2,5
18
14
6,0
10,0
10
8
3,4
5,7
7,5
12,5
2AD33-
2AD33-
0EA1
7EA1
E
30,0
37,0
40,0
50,0
47,3
57,2
59,0
72,0
62,0
75,0
72,0
87,0
75,0
90,0
100
125
3830
3832
1021-0
1022-0
25,0
25,0
6
3
3
35,0
35,0
2
2
2
25,0
25,0
6
3
3
35,0
35,0
2
2
2
22,0
22,0
48,0
48,0
10
(89)
2 Electrical Installation
2AD27-
2AD31-
2AD31-
5CA1
1CA1
5DA1
C
D
7,5
11,0
15,0
10,0
15,0
20,0
14,0
19,8
24,4
22,0
23,1
33,8
18,4
26,0
32,0
23,1
33,8
37,0
29,0
39,0
45,2
32
35
50
3812
3814
3820
*
*
1817-0
4,0
6,0
10,0
12
10
8
10,0
10,0
35,0
8
8
2
4,0
6,0
10,0
12
10
8
10,0
10,0
35,0
8
8
2
5,7
5,7
17,0
12,5
12,5
37,0
1,5
2,25
(13,3)
(20)
2AD34-
2AD35-
2AD37-
5FA1
5FA1
5FA1
F
45,0
55,0
75,0
60,0
75,0
100,0
68,6
83,8
110,5
87,0
104,0
139,0
90,0
110,0
145,0
104,0
139,0
169,0
110,0
145,0
178,0
160
200
250
3836
3140
3144
1224-0
1225-0
1227-0
35,0
70,0
95,0
2
2/0
3/0
150,0
150,0
150,0
300
300
300
50,0
70,0
95,0
1/0
2/0
3/0
150,0
150,0
150,0
300
300
300
75,0
75,0
75,0
165,0
165,0
165,0
50
(445)