Download Print this page
Panasonic EX-10 series Instruction Manual
Panasonic EX-10 series Instruction Manual

Panasonic EX-10 series Instruction Manual

Ultra-slim photoelectric sensor
Hide thumbs Also See for EX-10 series:

Advertisement

Quick Links

INSTRUCTION MANUAL
Photoelectric Sensor
EX-10 Series
Thank you for purchasing products from Panasonic Electric Works SUNX
Co., Ltd. Please read this Instruction Manual carefully and thoroughly for
the correct and optimum use of this product. Kindly keep this manual in a
convenient place for quick reference.
• Never use this product as a sensing device for personnel protection.
• In case of using sensing devices for personnel protection, use
products which meet laws and standards, such as OSHA, ANSI or IEC
etc., for personnel protection applicable in each region or country.
1
CAUTIONS
This product has been developed / produced for industrial use only.
For the convergent reflective type EX-14, maintain adequate distance
from reflective objects in the background, e.g. conveyors, since they may
adversely effect sensing.
2
A thin 0.1mm
cable is used for this product. Do not use excessive force
when pulling on the cable: it may cause cable to break.
Make sure that the power supply is off while wiring.
Incorrect wiring will damage the sensor.
Verify that the supply voltage including the ripple is within the rating.
Verify that the supply voltage variation is within the rating.
If power is supplied from a commercial switching regulator, ensure that
the frame ground (F.G.) terminal of the power supply is connected to an
actual ground.
In case noise generating equipment (switching regulator, inverter motor,
etc.) is used in the vicinity of this product, connect the frame ground
(F.G.) terminal of the equipment to an actual ground.
Do not run the wires together with high-voltage lines or power lines or put
them in the same raceway. This can cause malfunction due to induction.
You can extend the cable up to 50m max. with 0.3mm
both emitter and receiver. However, in order to reduce noise, make the
wiring as short as possible.
Do not use during the initial transient time (0.5s) after the power supply is
switched on.
Ensure that the sensor is not directly exposed to the following light
sources as they may adversely effect sensing performance: fluorescent
light from a rapid-starter lamp, a high frequency lighting device, sunlight
etc.
This sensor is suitable for indoor use only.
Avoid dust, dirt and steam. Do not use this sensor in places having
excessive vapor, dust, etc., or where it may come in direct contact with
corrosive gas.
Take care that the sensor does not come in contact with oil, grease,
organic solvents such as thinner, etc., strong acid, or alkalines.
Do not apply stress directly to the sensor cable joint by forcibly bending
or pulling.
Since the cable end is not waterproof, do not use the sensor in an
application where water could seep in from the cable end.
SEN TRONIC
AG
Produkte, Support und Service
Ultra-slim type
MEUEN-EX10 V2.0
WARNING
2
or more cable for
Rugghölzli 2
CH - 5453 Busslingen
2
MOUNTING
The tightening torque should be 0.2N·m or less.
Mounting using tapped holes
Side sensing
Sensing direction
10mm M2
Front sensing
7mm
Sensing direction
8mm M2
M2 x 0.4mm ø
When using the attached screws and nuts
Side sensing
Sensing direction
11mm
10mm M2
Thickness of mounting plate: 2mm or less
Front sensing
Spring washers
Flat washers
Sensing direction
8mm M2
Thickness of mounting plate: 2.5mm or less
1
Tel. +41 (0)56 222 38 18
Fax +41 (0)56 222 10 12
6mm
11mm
M2 x 0.4mm ø
11mm
Flat washers
Spring washers
11mm
mailbox@sentronic.com
www.sentronic.com

Advertisement

loading

Summary of Contents for Panasonic EX-10 series

  • Page 1 Side sensing  MEUEN-EX10 V2.0 Thank you for purchasing products from Panasonic Electric Works SUNX Co., Ltd. Please read this Instruction Manual carefully and thoroughly for the correct and optimum use of this product. Kindly keep this manual in a...
  • Page 2 MOUNTING BRACKETS I/O CIRCUIT DIAGRAMS When mounting the sensor with the optional mounting bracket, use the The following symbols are used in this section. attached M2 screws. The tightening torque should be 0.2N·m or less. Symbol Meaning Six types of optional sensor mounting brackets are available. Reverse supply polarity protection diode Model no.
  • Page 3: Specifications

    SPECIFICATIONS Convergent Thru-beam reflective Type Front sensing Side sensing Front sensing Side sensing Front sensing Front sensing Light- EX-11A(-PN/-R) EX-11EA(-PN/-R) EX-13A(-PN/-R) EX-13EA(-PN/-R) EX-19A(-PN/-R) EX-14A(-PN/-R) Model no. Dark- EX-11B(-PN/-R) EX-11EB(-PN/-R) EX-13B(-PN/-R) EX-13EB(-PN/-R) EX-19B(-PN -R) EX-14B(-PN/-R) Sensing range 150mm 500mm 2 to 25mm (Convergent point: 10mm) Min.

This manual is also suitable for:

Ms-ex10-1Ms-ex10-3Ms-ex10-2Ms-ex10-11Ms-ex10-12Ms-ex10-13